Replacing the 7100G-Series Fan Module
3-8
Troubleshooting
Replacing the 7100G-Series Fan Module
The 7100G-Series switch is cooled by a fan module accessible from the power supply side of the
unit. If the FAN LED and the output of the CLI
show system
command indicate that the fan
module has failed, you must replace the failed fan module.
The replacement fan kit, 71A-71GFAN, which you must order separately, contains one
replacement fan.
To replace the failed fan module:
1.
Unscrew the two captive screws of the failed fan module as shown in
2.
Following the discussion in “
Power Supply Air Flow and Switch Fan Module Air Flow
page 2-4, ensure that the new fan module air flow direction agrees with the installed 7100G-
Series switch configuration.
3.
If a non-default air flow is required, see “
Reversing the Fan Module Air Flow
directions on how to reverse the fan unit direction.
4.
Once you have ensured that the fan module air flow is appropriate to your system
configuration, slide the currently installed fan module forward until it is unplugged from the
device as shown in
.
Figure 3-4
Removing the Fan Module
5.
Align the new fan module with the fan module opening.
Note:
The 7100G-Series fan module is hot-swappable. Do not uninstall a failed fan module until its
replacement is available. All 7100G-Series switch components and cover plates must be installed to
ensure proper air flow.
1
Fan Module Screws
Содержание 7100G Series
Страница 2: ......
Страница 12: ...x...
Страница 20: ...Getting Help xviii About This Guide...
Страница 46: ...Completing the Installation Pin Out Descriptions 2 22 Installation...
Страница 58: ...Using the OFFLINE RESET Button 3 12 Troubleshooting...
Страница 62: ...Regulatory Compliance A 4 Specifications...
Страница 84: ...Management of PoE Power to PDs D 4 About PoE Power over Ethernet...