SAFETY INSTRUCTIONS
—
WARNING: Follow all safety and ventilation
regulations and follow all gas and liquid handling
procedures. Wear clothing and safety equipment
appropriate for the gas and liquid used. Wear
chemical-resistant work clothes and safety
glasses while changing and setting up the filter.
WARNING: If you do not follow the precautions,
the product may not perform properly or may
not be covered by the product warranty.
WARNING: Do not disassemble the manifold
product.
WARNING: Do not crush and do not expose the
manifold to any shock or force such as hammer-
ing, dropping, or stepping on it.
PREPARATION FOR INSTALLING
THE OPTIMIZER ST2 MANIFOLD
—
CAUTION: Before unpacking the product,
make sure the product matches the model
you ordered.
CAUTION: Once opened, products may not be
returned in some cases.
1. Determine the manifold mounting position
and prepare the required mounting holes or
conversion bracket.
CAUTION: Refer to the dimensions on pages 4 to
10 and secure the space required for replacing
and installing the fitting.
2. Place the manifold on a vertical surface of
sufficient strength so that the top of the mani-
fold is horizontal. Use a level if necessary to
ensure the manifold is level.
CAUTION: If the manifold surface is not horizon-
tal or the strength is insufficient, the liquid may
splatter when replacing the filter. Reinforce the
installation surface as necessary.
To minimize dripping when replacing the filter,
it is recommended to install a stop valve on the
vent and outlet lines with the shortest possible
pipe length.
If it is difficult to connect the tubing after
installing the manifold, connect tubing
before installing the manifold.
CAUTION: Make sure that no load is applied to
the connector due to the weight or layout of the
pipe. insufficient sealing may result and chemical
liquid leakage may occur.