AERONEX® H SERIES GAS PURIFICATION SYSTEM
Model EGPS8
Dimensional Information
System Connections
Enclosure Information
The ventilated enclosure is designed for indoor applications only. The enclosure has bolt down locations on
the bottom surface. The front panel is removable.
572 mm (22.50
″
)
Top view
379 mm (14.92
″
)
416 mm (16.38
″
)
1421 mm
(55.94
″
)
Side view
1
Touch screen
For system status and interface
2
Audible alarm
Audible warning informs of alarm condition
3
Start
Used to begin system operations and to clear alarms
4
EMO
When activated, power is removed from the cabinet. The system shuts down.
Front panel and controller remain powered.
5
Remote alarm interface
Allows for remote alarm input and output with female 15 pin DB connector
6
Instrument air
Supplies gas to the air-operated control valves
7
Regen gas vent
Exhaust regen gas
8
Exhaust vent
Allows ventilation
9
Process gas input
Inlet gas (not purified)
10
Circuit breaker
Provides additional electrical protection to the system and in some models
also acts as an ON/OFF switch for the system.
11
Reference
Atmospheric reference for the internal enclosure flow sensor
12
Process gas output
Outlet gas (purified)
13
A/C power input
Power connection
1
2
3
4
12
13
Front view
6
5
7
8
9
11
10