NT PRESSURE TRANSDUCER MODELS 4100, 4210
6
User Guide | Entegris, Inc.
Unit Operation
OPERATING ENVIRONMENT
—
The pressure transducer is to
be mounted in a well vented and
controlled environment. Refer to
the
Reference
section on page 10
for additional specifications.
PROCESS CONNECTION
—
To avoid possible pressure leaks,
make sure all process connections
have been performed in accordance
with the
Mechanical Installation
guidelines on page 3.
PRESSURE TRANSDUCER COVER
ASSEMBLY
—
NT Pressure Transducer covers are
factory sealed and should not be
tampered with or opened. Opening
the cover shall void the product
warranty.
WARNING! Any attempt to remove
or tamper with the transducer
cover will void the warranty
and damage the unit.
PRESSURE AND TEMPERATURE
REQUIREMENTS
—
The minimum pressure required
is atmospheric pressure. The pres-
sure transducer may be damaged
if subjected to vacuum pressure
(pressure that is less than atmo-
spheric pressure).
The pressure transducer is rated for
use with fluids at process tempera-
tures between 10–65°C (50–149°F)
under normal operating conditions.
WARNING! NT Pressure Transduc-
ers, Models 4100 and 4210 may be
damaged if the sensor is subjected
to any level of vacuum pressure
(pressure less than atmospheric
pressure).