1.Fan
speed
Ventilation
unit
has
three
options
for
choice
of
airflow.
Min,
Normal
and
Max.
For
programming
of
values
within
each
step,
see
4.5.1.3
Using
the
control
button
1,
and
‐
/
+
buttons
can
change
between
the
pre
‐
programmed
selections.
1.1
Fan
boost
Forced
ventilation,
fan
speed
increases
to
max
speed.
(Means
to
the
speed
that
is
set
in
menu
4.5.1.3.)
The
function
is
for
use
if
high
humidity
in
bathrooms
and
laundry
room.
Forced
ventilation
can
be
activated
with
button
then
Interval
adjustable
from
10
‐
240
min
with
+
and
‐
This
picture
shows
10
min
forcing
time,
but
not
activated.
To
activate
the
fan
boost
use
control
button
4.
You
can
see
that
the
fan
are
running
with
Max
speed
and
the
clock
will
start
countdown.
You
can
easy
deactivate
the
fan
boost
again
before
the
countdown
automatically
stops
it.
First
control
buttom
1
and
then
4.
This
feature
can
also
be
operated
with
an
external
pulse
switch.
The
switch
is
placed
in
the
bathroom
or
adjacent
rooms.
Connected
to
contact
D1
in
top
of
the
ventilation
unit.
(Look
at
page
23
in
this
manual.)
If
this
option
via
D1
is
intended
for
use
against
wood
stove
or
fireplace
then
it
is
recommended
that
Max
speed
under
Fan
control
in
menu
4.5.1.3.
is
set
to
Supply
100%
and
adjust
Extract
to
be
80
to
85%.
(Look
at
page
10
in
this
manual)
2.
Temperature
Choose
from
pre
‐
programmed
temperature
settings
set
point
between
15
‐
21
°C.
Setting
is
changed
by
operating
the
switch
buttons
below
‐
/
+
symbols.
Heating
element
can
here
be
set
ON
or
OFF
by
operating
the
switch
button
4
in
this
screen,
but
only
if
heater
is
connected.
(To
see
if
heating
coil
is
connected
or
disconnected,
see
4.5.1.1
Heater)
Indicator
for
activated
heating
coil.
Small
picture
show
not
activated.