Enso PB175 Скачать руководство пользователя страница 3

1

TO REDUCE THE RISK OF SHOCK, BURNS, FIRE OR INJURY:

For optimal safety and operation, plug bed base into a surge protector 

(not included).  The bed base should only be plugged directly into a wall 

outlet or surge protector (strongly recommended).   Always unplug the 

base from the electrical outlet before servicing any part of the base. To 

reduce risk of electric shock, unplug the base before cleaning. To safely 

disconnect, ensure the base is in a flat position with all motors off, and 

unplug from power source.  Keep the power cord away from heated 

surfaces. Never operate the base when the air openings are blocked. Keep 

air openings free of lint, hair and the like. Do not drop or insert any object 

into any opening.  Discontinue use of the bed base and contact a qualified 

service center if: it has a damaged cord or plug, if it is not working 

properly, or it has been dropped into water.  Only use this bed base for 

its intended use as described in this manual. Do not use accessories/

attachments that are not recommended by the manufacturer.  Close 

supervision is required when the bed base is used by or near children, 

convalescents, disabled persons or pets.  Improper connection of the 

equipment can result in the risk of electrical shock, electrical fire or faulty 

operation of this bed base. If the plug does not fit your outlet, contact a 

qualified electrician to install a suitable outlet. Unauthorized modification 

or failure to use a wall outlet or surge protector could void the electrical 

portion of your warranty.

PETS AND CHILDREN:

Immediately dispose of all packing materials as it may pose a smothering 

risk to small children and pets. To avoid injury, it is not advised to allow 

children and small pets to play on or under the bed. Children should not 

operate the bed base without adult supervision.

PACEMAKERS:

Some products contain Neodymium MAGNETS which may interfere 

with devices such as pacemakers, ICD’s and any other device sensitive 

to magnetic fields. It is STRONGLY recommended that owners of such 

medical devices consult their physician prior to using products that 

contain Neodymium MAGNETS.  It is also possible that some pacemakers 

may falsely interpret the optional massage feature vibrations as 

movement/exercise. This is a common occurrence with any product that 

creates a vibrating movement and may not affect the pacemaker. Please 

consult your physician before using the massage feature.

IN-HOME USE AND HOSPITAL STANDARDS:

Enso adjustable bed bases are designed solely for in-home use. This 

base was not designed as a hospital bed and is not designed to meet 

hospital standards. Do not use this base with TENT TYPE oxygen therapy 

equipment or near explosive gases.

ADDITIONAL SAFETY FEATURES

Casters (optional leg accessory) are equipped with locking wheels to 

prevent unwanted movement. Even when locked and unable to roll, it is 

possible for the casters to slide. Free release head and foot motors are 

designed to lower the mattress by retracting only with gravity, never 

pulling downwards, which minimizes pinch points

LIFTING/LOWERING MECHANISMS 

The lift/lower feature will emit a minimal humming sound during 

operation. This is normal. During operation, the lift arm wheels make 

contact with the platform support of the base.  This contact may result in 

metal on metal or metal on plastic contact. This applies slight tension on 

Attention: Important Safety Disclaimers

 

Read the following information before using this product. Failure to use a surge protection device could 

compromise safety or cause product malfunction and could void the electrical portion of your warranty. 

safety precautions and usage statements

Содержание PB175

Страница 1: ...Actual product appearance and functionality may vary from photographs illustrations and descriptions included in this manual OWNER S MANUAL PB175 ...

Страница 2: ...ons and Usage Statements 1 3 Parts List 4 Base and Remote Overview 5 Quick Reference Guide 6 Installation Guide 7 8 Connecting Strap 9 Syncing Two Bases 10 Headboard Brackets 11 Troubleshooting 12 Notes 13 Español 14 17 Français 18 21 ...

Страница 3: ...or under the bed Children should not operate the bed base without adult supervision PACEMAKERS Some products contain Neodymium MAGNETS which may interfere with devices such as pacemakers ICD s and any other device sensitive to magnetic fields It is STRONGLY recommended that owners of such medical devices consult their physician prior to using products that contain Neodymium MAGNETS It is also poss...

Страница 4: ...ocess to ensure bases will operate within these standards during normal operating use Normal operating use is defined as the following Adjustable foundation is to be operated with a mattress and load Testing procedures require lifetime cycle tests with up to 120kg distributed load The angle designated α in figure 1 between the back section and the flat section for various configurations of the mat...

Страница 5: ...sistent marks remain visible after cleaning seek professional advice PRODUCT RATINGS The lift motors are not designed to operate continuously for more than 2 minutes in an 18 minute time period or approximately 10 duty cycle Attempting to circumvent or exceed this rating will shorten the life expectancy of the product and may void the warranty The massage motors are not designed to operate continu...

Страница 6: ...otector Headboard Bracket Components I Headboard Bracket 2 J T Bracket 2 K Spacer 2 L Long Bolts 8 M Short Bolts 10 N Nuts 18 These items are attached to the base for shipping purposes Carefully remove from base and set aside Only included in Twin Long and Cal King Split bases This is an optional item and can be purchased by calling 1 844 534 3676 Before discarding the packing materials ensure all...

Страница 7: ...5 base and remote overview Head Motor Lowers head portion of the base Lifts head portion of the base ...

Страница 8: ...erence guide Not to scale For illustration purposes only Read all instructions before beginning installation ELECTRONICS OVERVIEW If installing a split unit see pages 9 10 Remote Head Motor Power Cord Power Supply ...

Страница 9: ...Remove the binding straps and packing materials making sure not to puncture the box with any sharp objects Remove the bed base from the box keeping the bottom of the base facing upwards STEP 3 To install the legs unscrew the spacer on the four bed leg hole sites thread the washer over the bolt of the leg with the recessed side facing the leg and tighten by hand Do not over tighten 9 inch leg 9 inc...

Страница 10: ...se to a flat position before placing the mattress on top Setup is now complete Test all functions on remote Slide the left side of the mattress retainer bar into the bracket Pull the retainer bar to the opposite bracket and secure the right side For customer support visit www ergomotion com or call 1 844 534 3676 STEP 4 STEP 5 Uncoil power connection cord from the head actuator and plug into Power...

Страница 11: ... strap and connect side b to the leg bolt Secure the strap by shifting to the left Re tighten legs Do not over tighten Use the remaining strap and repeat on other end of the base STEP 2 STEP 1 STEP 3 connecting strap optional a b If a split setup is being installed optional plastic connecting straps can be used to help secure the bases together To purchase optional accessories please call 1 844 53...

Страница 12: ... connected to the motor Plug end of y cord into wired control plug Repeat for other end of cord and wired control plug from second motor Once the remote has been connected to the control box with the y cord plug bases into power outlet and test all functions Plug remote into Y Cord Unplug bases from power source STEP 3 STEP 2 STEP 1 STEP 4 syncing two bases optional Remote Y Cord Motor Bed A Motor...

Страница 13: ...ll the spacer and attachment plate to accommodate the headboard b To install the plastic spacer and attachment plate you will need 2 long bolts and 2 nuts Place the spacer and attachment plate in the desired location and slip the bolts through the holes with the head of the bolt facing outward Position the bolts diagonally on the spacer Use the 9 16 14 mm socket and wrench to tighten the bolts You...

Страница 14: ...power cords are properly connected Unplug the base for 1 hour to reset the electronic components Plug bed base into a different electrical outlet or test current outlet with another working appliance a grounded electrical surge protector is recommended If issue is not resolved by following the instructions above locate serial number on warranty card or back of remote and call Ergomotion Customer S...

Страница 15: ...13 notes ...

Страница 16: ...tía visite www ergomotion com o lea la tarjeta de garantía incluida en la base Uso doméstico y renuncia de responsabilidad legal por uso en hospitales Las camas de base ajustable de Enso están diseñadas solamente para uso doméstico Esta cama no fue diseñada para su uso en hospitales y no está diseñada según las normas de los hospitales No use esta cama con equipos como cámaras para terapia de oxíg...

Страница 17: ... Antes de eliminar los materiales de empaque verifique que tiene todos los componentes Todas las partes electrónicas y los componentes que necesitan instalarse están en cajas debajo de la base o adheridos al marco A Wired Remote Control 1 Con cables Contro Remoto 1 B Mattress Retainer Bar 1 Barra de retención del colchón 1 C Legs 6 Patas 6 D Power Cord 1 Cable eléctrico 1 E Power Supply 1 Fuente d...

Страница 18: ...tas para verificar la instalación correcta antes de colocar el colchón en la base Vuelva la base de una posición plana antes de colocar el colchón en la parte superior PASO 10 Deslizar el lado izquierdo de la barra de retención en el soporte de colchón Tire de la barra de retención en el soporte opuesto y lograr la derecha La configuración habrá finalizado Pruebe todas las funciones de control rem...

Страница 19: ...fijación en la ubicación deseada y el deslizamiento de los pernos a través de los agujeros con la cabeza del perno hacia afuera Coloque los tornillos en diagonal sobre el separador Utilice la opción toma y llave de 9 16 para apretar los tornillos PASO 3 Ahora puede conectar el cabecero de las placas de fijación usando los tornillos cortos restantes y tuercas para fijarlo a los soportes Las cabezas...

Страница 20: ...ables de Enso sont créés pour l utilisation individuelle à la maison Cette base n est pas créée pour l utilisation comme lit d hôpital et elle ne satisfait pas les critères d hôpital N utilisez pas cette base avec l équipement de l oxygénothérapie ou près des gazes explosives Les animaux domestiques et les enfants Jetez immédiatement les matériaux d emballage parce qu ils posent un risque d asphyx...

Страница 21: ...sont prises en compte Tous les composants électriques qui doivent être installés se trouvent dans les boîtes sous la base ou sont attachés à la charpente A Wired Remote Control Télécommande filaire 1 B Mattress Retainer bar Barre de soutiens du matelas 1 C Legs Pieds 6 D Power Cord Cordon d alimentation 1 E Power supply Alimentation électrique 1 F Y Cord Cordon en Y Pièces Divers non inclus G Conn...

Страница 22: ...ns le support Tirez la barre de soutiens du matelas dans le support opposé et attachez le côté droite L installation Élémentaire Est Complète Pour service consommateurs allez au site web www ergomotion com ou appelez le numéro vert 1 844 534 3676 Pg 9 Joindre deux Lits en option Si une configuration partagée est en cours d installation de sangles en plastique de connexion optionnels peuvent être u...

Страница 23: ...es boulons diagonalement sur la cale d espacement Utilisez le 9 16 socket et la clé à molette pour serrer les boulons Étape 3 Maintenant vous pouvez attacher le dosseret aux plaques d attachement en utilisant les boulons courts et les écrous pour l attacher dans les équerres Les têtes des boulons doivent être vers l extérieur Utilisez le 9 16 socket et la clé à molette pour serrer les boulons Pg 1...

Страница 24: ...Nationwide Customer Service Phone 1 844 534 3676 Fax 1 805 979 9399 Email info ergomotion com Web www ergomotion com 2016 Ergomotion Inc V001_07 2016 Serial Number ...

Отзывы: