MODULE OVERVIEW
The 5820 GPI/Serial Interace module extends the capability of the Avenue control system
by enabling third party interfaces to control Avenue modules through memory register
recall. The 5820 provides General Purpose Interface control (GPI contact closure) over
modules located anywhere in the Avenue system. It also provides RS-232/RS-422 serial
interface access for use with show controllers and automation systems.
As shown in the block diagram below, GPI or serial inputs from a third party device, such
as an automation system, enter the 5820 module. They are mapped using the 5820 GPI
menus to any Avenue module in the network. When a GPI or serial command is received
by the 5820, it sends a configuration recall command to the corresponding Avenue module.
Using M2M™ (Module To Module) communication, the 5820 can communicate with any
other module in any Avenue frame on the network. That module then recalls the specfied
memory register.
An optional 1 RU control panel is available to serve as a shot box. It has eight illuminated
status pushbuttons that can also be used for manual override and status in automated
systems. Configuration and monitoring of the 5820 can also be done through an optional
Avenue Touch Panel, your web browser, and Avenue PC software.
Model 5820 GPI/Serial Interface Module
5820-2
GPI
Inputs
Control
Processor
RS-232/
RS-422
Communication
With Other Modules
Through Avenue
Control System
5820 GPI/Serial Interface Module Block Diagram