Models 5360 and 5365 Four Channel Analog to Digital Video Converters and Embedders
MODULE CONFIGURATION AND CONTROL
The configuration parameters for each Avenue module must be selected after installation.
This can be done remotely using one of the Avenue remote control options or locally using
the module front panel controls. Each module has a
REMOTE/LOCAL
switch on the
front edge of the circuit board which must first be set to the desired control mode.
The configuration parameter choices for the module will differ between
Remote
and
Local
modes. In
Remote
mode, the choices are made through software and allow more
selections. The
5360 and 5365 Parameter Tables
later in this section summarize and
compare the various configuration parameters that can be set remotely or locally and the
default/factory settings. They also provide the default User Levels for each control. These
levels can be changed using the Avenue PC application.
If you are not using a remote control option, the module parameters must be configured
from the front panel switches. Parameters that have no front panel control will be set to a
default value. The
Local
switches are illustrated in the
Front Panel Controls and
Indicators
section following the
5360 and 5365 Parameter Tables
.
Avenue module parameters can be configured and controlled remotely from one or both of
the remote control options, the Avenue Touch Screen or the Avenue PC Application. Once
the module parameters have been set remotely, the information is stored on the module
CPU. This allows the module to be moved to a different cell in the frame at your discre-
tion without losing the stored information. Remote configuration will override whatever
the switch settings are on the front edge of the module.
For setting the parameters remotely using the Avenue PC option, refer to the
Avenue PC
Remote Configuration
section of this document.
For setting the parameters remotely using the Avenue Touch Screen option, refer to the
Avenue Touch Screen Remote Configuration
section of this document following
Avenue PC.
Express Panel operation is described in the data pack that accompanies the control panel
option.
5360-8