Front Panel Controls and Indicators
Each front edge indicators and switch settings are shown in the diagrams below:
4
Channel
ADC / TBC
Input 1
Input 2
Input 3
Input 4
Ref Pres
Remote
Local
TBC 1
TBC 2
TBC 3
TBC 4
Run
Pwr
5360
on
Remote/Local
switch:
Set to the mode you
will be using.
Pwr
green LED:
Indicates the presence (
ON
) or
absence (
OFF
) of power (+5V).
Run green
LED:
OFF
:
A power fault or halted CPU
ON
:
A halted CPU
FAST BLINK
:
CPU Run error
SLOW BLINK
:
System OK. (If SPI control
is active from the main
frame System Control
Module, all
Run
indicators
will be synchronized.)
Ch 1-4 Input
green LEDs:
On
indicates input video signal
is present and detected on each
individual channel.
OFF
no input video signal detected
on the input of each channel.
Ref
green LED:
On
when the external reference
source is detected.
OFF
when no reference signal is
detected.
TBC 1-4
switches:
Turn Time Base Correction
On
(left)
or
Off
(right) for each individual
channel with the corresponding
TBC 1-4
switches.
Models 5360 and 5365 Four Channel Analog to Digital Video Converters and Embedders
5360-11