Ensemble Designs Avenue 5030 Скачать руководство пользователя страница 7

www.ensembledesigns.com

    Page 7

Model 5030/5035 System Control Module 

 

 

 

 

 

          User Guide

The Status menus available are explained below. 

Use S3 to scroll through the menu selections. When you reach the desired selection, use S1 or Enter 
(S4) to access the menu. Set the desired parameters inside each menu selection with S3. Press Enter 
(S4) to finalize your selection and exit the menu. Note that using S1 to access a menu allows you to 
read the assigned parameter and exit without changing it. If you use Enter (S4) to access a menu, you 
must set a parameter with S3, then press Enter (S4) again to set the selection and leave the menu. 

Ver

Adr

V  ip

ip1

ip2

ip3

ip4

Tch

1.5.0

1 - 1023

1 - 1023

192.168.0.10

Press Ent to Reset 

Touch Panel

XXX.168.0.10

192

.XXX.0.10

192.168.

XXX.10

192.168.0.

XXX

Use S1 to enter the menu. The current version of system 
software on the Control Module will scroll through the display.

Use S1 to enter the menu. The current AveNet address of this 
Control Module will be displayed. To change address, use S3 to 
move to the desired number. Press S4 to set the parameter and exit.

Use S1 to enter the menu. The current IP address of this 
Control Module will be displayed. To change address, 
To change address, use ip1-4 below.

Use S1 to enter the menu. Set the first segment of the IP address 
by using S3 to scroll through the numbers 0-255. Press S4 to set
the parameter and exit the menu.

Use S1 to enter the menu. Set the second segment of the IP address 
by using S3 to scroll through the numbers 0-255. Press S4 to set
the parameter and exit the menu.

Use S1 to enter the menu. Set the third segment of the IP address 
by using S3 to scroll through the numbers 0-255. Press S4 to set
the parameter and exit the menu.

Use S1 to enter the menu. Set the fourth segment of the IP address 
by using S3 to scroll through the numbers 0-255. Press S4 to set
the parameter and exit the menu.

Press the ENTER button, S4, to reset the calibration on
the Touch Screen Panel.

Avip

On/Off

Use S1 to enter the menu. Use S3 to turn AveNet Over IP on or off.
Press S4 to set the parameter and exit the menu.

Lo A

Use S1 to enter the menu. Use S3 to  scroll to the 
upper (highest) AveNet address in the frame group. Use S4 to set the 
parameter and exit the menu.

Use S1 to enter the menu. Use S3 to  scroll to the 
lowest AveNet address in the frame group. Use S4 to set the 
parameter and exit the menu.

1 - 1023

Up A

S3

S1

Enter/Exit

Содержание Avenue 5030

Страница 1: ...www ensembledesigns com 9600 1 Model 9600 3G HD SD Embedder Disembedder and Data Inserter Model 5030 5035 System Control Module User Guide Revision 3 2a SW v2 2 13 ...

Страница 2: ...his business and we re here to stay Bricks and Mortar of Your Facility The bricks and mortar of a facility include pieces like up downconverters audio embedders video converters routers protection switches and SPGs for SD HD and 3Gb s That s what we re focused on that s all we do we make proven and reliable signal processing and infrastructure gear for broadcasters worldwide for you Who is Ensembl...

Страница 3: ...stem Control Module User Guide Contents Module Overview 4 Installation 5 1RU Frame 5 3RU Frame 5 Cabling 3RU Frame Only 5 Front Panel Controls and Indicators 5 Updating Software for the 5030 or 5035 8 Troubleshooting 12 Warranty 12 Factory Service 12 ...

Страница 4: ...the serial communications port the AveNet LAN connection the AveNet Over IP function and the Ethernet TCP IP connection The System Control module distributes a master timing reference from the rear backplane BNC to all modules in a frame Front panel indicators include network communication serial communication reference signal presence and power CONTROL MODULE AVENUE MODULES VIDEO AUDIO COMMUNICAT...

Страница 5: ...d Indicators The status indicators and controls on the front edge of the 5030 5035 System Control modules are illustrated below The Status menu display is used for various purposes It acts continuously as a status indicator for showing system communication between the Avenue frame and external Ethernet Serial and External Reference connections A series of menu functions can also be accessed throug...

Страница 6: ...www ensembledesigns com Page 6 Model 5030 5035 System Control Module User Guide N S R S1 Reset Reset Run Run S3 S4 N S R S1 S3 S4 5035 Front Controls 5030 Front Controls ...

Страница 7: ... the menu The current IP address of this Control Module will be displayed To change address To change address use ip1 4 below Use S1 to enter the menu Set the first segment of the IP address by using S3 to scroll through the numbers 0 255 Press S4 to set the parameter and exit the menu Use S1 to enter the menu Set the second segment of the IP address by using S3 to scroll through the numbers 0 255...

Страница 8: ...e to your Avenue module If you do not have Avenue PC software you can send modules back to the factory for software upgrades 1 Download the current version of the 5030 5035 software to your desktop from the following link http www ensembledesigns com support avenue support avenue software 2 From Avenue PC select Update Frame Software from the Frame menu The initial Download Software window display...

Страница 9: ...ate to the downloaded software file and select it It will have the file extension msf 5 With the downloaded software file selected click Open The Download Software window displays again This time it has the filename of the software update file showing next to the Select File button The initial Download Software window Navigating to and selecting the downloaded software file ...

Страница 10: ...le User Guide 6 Click Download Now The Download Software window displays showing the progress of the download from your computer to the 5030 or 5035 The Download Software window showing the selected software update file The Download Software window showing its progress ...

Страница 11: ...leted From the Home screen select Configuration The Configuration screen displays as shown below 7 When the software has finished downloading to the module it will display End as shown in the screen capture below The software has finished downloading to the 5030 or 5035 The Touch Screen Configuration Screen showing the software version installed on the 5030 ...

Страница 12: ... the main Preface of this manual If you require service under warranty or not please contact Ensemble Designs and ask for customer service before you return the unit This will allow the service technician an opportunity to provide any other suggestions for identifying the problem and to recommend possible solutions Factory Service If you return equipment for repair please get a Return Material Aut...

Отзывы: