MASTERS DECORATIVE SERIES

IN-WATER COMPONENTS PRODUCT WARRANTY (LIMITED)

AQUAMASTER®

, hereinafter referred to as The Seller, warrants your Series 304 

and/or Series 316 Stainless Steel motor and seal assembly, float and underwater 

power cable (referred to as in-water components) for a period of 5 years on parts 

and labor with the upgraded control panel (3 years with the standard control 

panel), 

when used in fresh water only

. This coverage is at 100% replacement 

costs, should it fail due to defects in materials or workmanship, during the 5 year 

(3 year) period. This is in effect from the date of shipment, when given normal 

and proper usage as determined by The Seller or its authorized representative 

upon examination, and when owned by the original user. 

Please note that normal 

and proper usage does not include any salt water or highly brackish water 

conditions. Series 316 Stainless Steel units must be used for these conditions. 

SERIES 316 STAINLESS STEEL 

IN-WATER COMPONENTS PRODUCT WARRANTY

The Seller warrants your Series 316 Stainless Steel in-water components 

for a period of 3 years on parts and labor, when operating in any salt water 

or highly brackish water conditions. This coverage is at 100% replacement 

costs, should it fail due to defects in materials or workmanship, during the 3 

year parts and labor period. This is in effect from the date of shipment, when 

given  normal  and  proper  usage  as  determined  by  The  Seller  or  its  authorized 

representative upon examination, and when owned by the original user.

ELECTRICAL CONTROL PANEL AND 

THEIR COMPONENTS PRODUCT WARRANTY

The Seller warrants all parts of its electrical control panel and their components 

against defects in material or workmanship for a period of 3 years on parts and 

labor with the upgraded control panel (1 year with standard control panel)from 

date of shipment when given normal and proper usage as determined by The 

Seller upon examination, and when owned by the original user.  Components 

purchased by The Seller as complete units and used as an integral part of The 

Seller’s equipment will be covered by the standard warranty of the manufacturer 

thereof.  The Seller will repair or replace F.O.B. original shipping point (but not 

install) any part or parts of its manufacture which in its judgment shall disclose 

defects in either material or workmanship. If requested by The Seller, parts for 

which a warranty claim is made are to be returned transportation prepaid to our 

Factory. This warranty becomes void if the article claimed to be defective has been 

repaired or altered in any way, or if the unit has been subject to misuse, negligence 

or accident, or when instructions for installing or operating have been disregarded.  

It is recommended that the enclosed warranty card is returned to The Seller. 

A  return  authorization  number  must  be  obtained  prior  to  any  required  return.  

We make no other warranty, expressed or implied, and make no warranty 

of  merchantability  or  of  fitness  for  any  particular  purposes,  and  there  are  no 

warranties which extend beyond the description of the face hereof.  No employee 

or representative is authorized to change this warranty in any way or grant any 

other warranty.  The remedies hereinabove afforded to original user are exclusive 

of all other remedies provided by law.  The Seller shall not be liable for indirect 

or consequential damages where the loss sustained is of a commercial nature.

Page 22

Содержание AquaMaster Masters Decorative Series

Страница 1: ... HP Masters Decorative Series 60Hz Owner s Manual A DIVISION OF ENQUATICS INC ...

Страница 2: ......

Страница 3: ...T use in swimming or marine areas Only qualified personnel shall service and install AquaMaster pumps or lighting systems Installation and service to be in accordance with the National Electric Code and local codes and or ordinances This unit is intended to be operated only after it is properly installed anchored and wired Risk of electrical shock DO NOT operate this unit dry unless testing for pr...

Страница 4: ...Lamp Replacement 24 Troubleshooting Guide 25 ElectricalWiringDiagram 26 AquaLock ALC ComponentsView 27 Internal Fountain Components List 28 Internal Parts Drawing 29 Power Units Parts Lists 30 Power Unit Drawing 31 SHIPPING CLAIMS When you receive your AquaMaster unit examine the package for any signs of external damage it may have sustained enroute If there is apparent damage either outside the b...

Страница 5: ...he impeller housing The float must be installed as shown with the inner ring toward the motor Installing the float upside down will adversely affect its performance 2 Using the 3 16 Allen wrench install four 4 of the 20 socket head cap screws into the upper float tube mounting holes These holes are closest to the grooved end of the float tube DO NOT over tighten the screws 3 Slide the float up unt...

Страница 6: ...hey are not extending beyond the inner mounting surface If they are back the thumbscrews out until the tips are flush with the inner mounting surface This will allow for easy installation onto the float tube 2 Install the o ring provided into the top float tube groove This may have been done at the factory 3 Liberally apply grease provided to the inside of the nozzle mounting surface and the o rin...

Страница 7: ...our power unit and the other half to your cable end When you remove the protective caps keep them in a safe place such as the control panel 2 Connect the two halves of the ALC together CAUTION HAND TIGHTEN ONLY DO NOT use tools such as a pipe wrench or pliers as you may over tighten and damage the connectors 3 Locate the cable support grip and clip it onto the snap clip located on the motor housin...

Страница 8: ...the bottom with a 3 8 locking nut and washer 4 Tighten the nut using 2 9 16 wrenches or pliers DO NOT over tighten 5 Make sure the light retaining clips are in the open position The clips are positioned without the use of tools 6 Insert the light housing from the top down as shown in Figure 2 Figure 2 Light Housing Light Retaining Clips Page 5 Figure 1 3 8 16 SS Bolt 3 8 SS Extra Thick Washer Ligh...

Страница 9: ...INSTRUCTIONS CONT 7 When the light housing is seated into the bracket turn the retaining clips to ensure the housing is as shown in Figure 3 8 After fixtures are installed on the float connect the AquaLock ALC ends together HAND TIGHTEN ONLY Page 6 ...

Страница 10: ...t breaks or splices ELECTRICAL CONNECTION TO CONTROL PANEL TIMER PANEL ASSEMBLY 1 The unit comes with a timer panel that must be mounted vertically with the cord holes downward to a solid structure Correct mounting will prevent rain entry into the timer panel 2 Once the panel is securely mounted open the front cover and plug the timer panel into a 120V outlet using the power cord supplied 3 Before...

Страница 11: ...aning of the lenses may become necessary Your line voltage 120 Volt lighting system was designed with your safety in mind They include the following A GFCI Protection in main fountain timer panel B 120 Volt 11 Watt LED lighting C Timer Box WARNING Your lighting system is pre wired and is provided with a GFCI for your safety and the safety of your equipment in event of an electrical short ground or...

Страница 12: ...n or animal in contact with the water ELECTRICAL CONNECTION TO CONTROL PANEL TIMER PANEL ASSEMBLY 1 The unit comes with a timer panel that must be mounted vertically with the cord holes downward to a solid structure Correct mounting will prevent rain entry into the timer panel 2 Once the panel is securely mounted open the front cover and plug the timer panel into a 120V outlet using the power cord...

Страница 13: ...240V units the overload relay must be set to the motor nameplate value plus two 2 amperes BEFORE INSTALLING INTO THE WATER test the unit briefly 30 seconds or less to make sure it runs and check for proper rotation counter clockwise looking down from top of power unit Listen for any unusual noises Unit should run smoothly and quietly If single phase rotation is backwards PLEASE CONTACT THE FACTORY...

Страница 14: ...TING THE CLOCK 1 Press and hold the CLOCK button 2 While holding the CLOCK button press the DAY HOUR or MINUTE button to the desired day time Note You must advance past 12 00 to set PM 3 Release the CLOCK button Reset Button Minute Button Hour Button Timer Button Clock Button On Button DIGITAL TIMER OPERATING INSTRUCTIONS Page 11 ...

Страница 15: ...h Fr Sa Su 4 Press the HOUR MIN button repeatedly for desired ON time Note You must advance past 12 00 to set PM 5 Press the TIMER button once 1OFF appears 6 Press the DAY button repeatedly for desired days OFF Note Must match 1ON day settings 7 Press the HOUR MIN button repeatedly for desired OFF time Note You must advance past 12 00 to set PM 8 Repeat steps 1 through 7 for more events if desired...

Страница 16: ... until 30 PM appears 4 Press the CLOCK button to execute the program 5 Press the MANUAL button until the line is above AUTO Program Example 2 3 Event Program Event 1 Turn timer ON at 7 30 AM and OFF at 11 30 PM Monday through Friday Event 2 Turn timer ON at 8 00 AM Saturday and turn timer OFF at 2 00 AM Sunday Event 3 Turn timer ON at 9 00 AM Sunday and turn timer OFF at 10 00 PM Sunday This is a ...

Страница 17: ...pears 3 Press the TIMER button until 2OFF appears EVENT 2 OFF Timer is OFF at 2 00 AM Sunday 1 Press the DAY button until Su appears 2 Press the HOUR button until 2 00 AM appears 3 Press the TIMER button until 3ON appears EVENT 3 ON Timer is ON at 9 00 AM Sunday 1 Press the DAY button until Su appears 2 Press the HOUR button until 9 00 AM appears 3 Press the TIMER button until 3OFF appears EVENT 3...

Страница 18: ...he timer Turn the cover one quarter turn clockwise and remove the cover 3 Using a small screwdriver pry out the battery Install the new battery and replace the cover Note The timer settings will be retained for approximately one 1 minute once the battery is removed Note The battery can be purchased in most local drug and big box stores TEMPORARY OVERRIDE 1 When the timer s output status is ON Pres...

Страница 19: ... into pond s edge Anchoring Steps 1 With the unit fully assembled and still on shore attach anchor lines to the float Only use the anchor holes which are opposite from one another Next carefully lower unit into the pond DO NOT tangle anchor lines and electrical cable s 2 Once the unit is floating freely hold or secure one anchor line With second line walk slowly away from the first stake to opposi...

Страница 20: ...varies more than three feet use FIGURE 1 Two 2 anchors eight inch concrete blocks approximate weight of 30 pounds each is sufficient Anchoring Steps 1 With unit fully assembled and still on shore attach anchor lines to the float Only use the anchor holes which are opposite from one another Next carefully lower unit into the pond DO NOT tangle anchor lines and electrical cable s 2 Position unit at ...

Страница 21: ...termediate weights of approximately 5 lbs each should be secured to your anchor lines These weights will keep tension on your anchor lines even though the water depth may vary 4 Stretch out your anchor lines so your intermediate weights are suspended in the water and not sitting on the bottom When the anchor lines are properly stretched out fasten them securely to your anchors on shore or the bott...

Страница 22: ...iate weights can also be used with all kinds of anchoring to keep constant tension on the anchor lines when the pond depth varies Follow the installation instructions from the previous page Intermediate Weight Optional Stake Stake Page 19 ...

Страница 23: ...y evidence of this an annual maintenance should be performed oil and seal change to keep your unit running properly and warranty in effect Check motor bearings by turning impeller or propeller shaft by hand it should turn smoothly and quietly Visually inspect the power cable making sure there are no cuts worn spots or animal chew marks If any damage has occurred replacement of the cable must be do...

Страница 24: ...ive in a potentially cold climate The removal of your AquaMaster unit before freezing conditions occur is a perfect opportunity to inspect your unit and keep it running trouble free If you have freezing temperatures for short periods of time you can decrease the chance of freezing by running the unit for 24 hours a day NOTICE Freeze damage to any component of your AquaMaster unit or lighting syste...

Страница 25: ...rts of its electrical control panel and their components against defects in material or workmanship for a period of 3 years on parts and labor with the upgraded control panel 1 year with standard control panel from date of shipment when given normal and proper usage as determined by The Seller upon examination and when owned by the original user Components purchased by The Seller as complete units...

Страница 26: ...ng the 3 year period halogen lamps have no warranty This is in effect from the date of shipment when given normal and proper usage as determined by The Seller or its authorized representative upon examination and when owned by the original user Please note that normal and proper usage does not include any salt water or highly brackish water conditions Series 316 Stainless Steel units must be used ...

Страница 27: ...028 920028 2 Clamp 880004 880004 3 Clear Lens and Gasket Assembly 761079 761079 4 Light Plate Assembly CBA11 761042 5 Potting Resin 880128 880128 6 Power Supply Kit 880186 N A 7a Housing Single 880044 880044 7b Housing Double 880045 880045 8 Cord Connector 860016 860015 9 ALC Assembly 760512 SS 760975 10 Kit O Ring Wire Nut 760830 761087 Select a Board color Amber Blue Green Red White 1 2 HP 120 V...

Страница 28: ...attern is erratic The propeller is loose or missing Tighten or replace the propeller assembly The propeller is bent Replace the propeller diffuser assembly Debris in the propeller diffuser assembly Clean the debris out NOTE Plastic bags plastic wrap on the propeller and shaft This must be cleaned out for proper performance The nozzle is clogged The intake screen is clogged Remove the nozzle and cl...

Страница 29: ...DWG NO 111GFM CLASSIC LE PE Page 26 ...

Страница 30: ...MATCHING WIRE COLOR TO PIN LOCATION FOR AQUALOCK ALC USE FOR DIAGNOSTIC PURPOSES ONLY Page 27 ...

Страница 31: ...Page 28 ...

Страница 32: ...MD002 609 Page 29 ...

Страница 33: ...Page 30 ...

Страница 34: ...MD002 249 Page 31 ...

Страница 35: ...Page 32 Standard Panel Upgraded Panel ...

Страница 36: ...Notes Page 33 ...

Страница 37: ...one Fax Toll Free Visit Floating Fountains Masters Series Masters Decorative Series Celestial Fountains Fixed Base Fountains Fixed Base Fountains Series Aeration Volcano II Hydromax Series AquaAir Aeration Systems Oxymax and Ultimax Subsurface Aeration Systems Lighting and Accessories Night Glow Lighting and Control Panel LED Lighting System A DIVISION OF ENQUATICS INC ...

Отзывы: