AC Battery Installation
© 2016 Enphase Energy Inc.
141-00036 Rev 01
24
Technical Data
Model Number
Enphase AC Battery
(B280-1200-LL-I-US00-RF0)
AC Battery with integrated S280-ACB-LL-US Enphase Microinverter
Accessories
Enphase wall-mount bracket
Order separately:
BWM-16IN-B: 487 mm (W) x 356 mm (H) / 19.2 in. (W) x 14.0 in. (H)
accommodates 16 in. battery to battery spacing
Weight: 3.65 kg (8.05 lbs.)
Output Power
Peak output power
280 VA
Rated (continuous) output power
270 VA
Nominal voltage
~25.6 V
Maximum voltage
28 V
Extended line to neutral voltage range
211 - 264 VAC
Nominal output current
1.13 A
Nominal frequency / range
60 Hz / 57 - 61 Hz
Extended frequency range
57 - 63 Hz
Power factor (adjustable)
1 / 0.7 leading . . . 0.7 lagging
Maximum units per 20 A branch circuit
14 (single phase)
Peak inverter efficiency
97.3%
Battery Chemistry
Capacity
1.2 kWh
Depth of discharge (usable capacity)
>95%
Ambient temperature range
-4ºF (-20ºC) to 113ºF (45ºC)
Chemistry
Lithium Iron Phosphate (LFP)
Cell safety certifications
TUV Rheinland, UL
Roundtrip cell efficiency
1
96%
Mechanical Data
Dimensions
390 mm (W) x 325 mm (H) x 220 mm (D) / 15.4 in (W) x 12.8 in (H) x 8.7 in (D)
(without bracket)
Weight
55 lbs. (25 kg)
Installation
Wall-mounted in an indoor space using standard AC wiring in conduit or in
wall, where allowed.
Enclosure
Indoor – IP20
Cooling
Natural convection: No fans.
Grid configuration
TN-C-S
Features and Compliance
Compatibility
Compatible with grid-tied PV systems using the Enphase Envoy-S™ Metered
gateway.
Communication
Power Line Communication (PLC), TCP/IP through Envoy-S.
Services
Maximizing self-consumption of solar, time-of-use bill management, power
export limiting
2
Monitoring
Enlighten Manager and MyEnlighten monitoring options
Compliance
UL 991, UL 1642, UL 1741, UL 1973, UL 9540; UN 38.3
1
At 25°C
2
Optional. Requires Enphase S-Series Microinverters to implement.