7
en
Fill the Reservoir
Remove the fill cap to fill the reservoir with 14 oz of clean, cold
potable water. While holding the unit in the horizontal position, fill
reservoir about half full. Securely replace the fill plug. Turn bottle
in vertical position and check fill line. Repeat until water reaches
fill line. Do not overfill. Do not fill with hot water.
Prime the Spray Bottle
When new, or after long storage, the ozone generator cell in the
bottle may become de-primed and dry. In this condition the blue
light will not illuminate while spraying and the red and blue lights
will flash twice when the trigger is released.
To prime the spray bottle, continue to spray with the blue light
off until the blue light turns on and remains on. If the blue light
does not illuminate after 2 minutes of spraying, adding ordinary
table salt to the tank will help prime the ozone cell. Fill the tank
with fresh tap water. Add and mix one teaspoon (5 grams) of salt
into the tank. Spray out the entire tank of water into a sink. Fill
the tank with fresh tap water and spray 30 seconds. Your bottle is
now ready to use. The salt procedure may have to be repeated if
the bottle sits unused for an extended period.
Sanitize Hard Non-Porous Surface
Hold the spray bottle 6 to 8 inches from the surface and spray
evenly until wet. For 99.9% effectiveness against common
pathogens allow to stand for 30 seconds. Wipe with a clean
cotton or microfiber cloth or allow to air dry. No rinsing is
necessary (leaves no residue). Ozone is generated on demand.
While spraying, the blue indicator will light when the unit is
operating properly. Improper use of this product may affect
cleaning performance and may increase the risk of health effects.
CAUTION
FILL WITH CLEAN, COLD POTABLE WATER ONLY.
DO NOT OVERFILL THE BOTTLE.
DO NOT RUN WATER INTO THE CHARGER PORT.
WATER TEMPERATURE 40 °F to 86 °F (4 °C to
30 °C)
Hold 6-8” away from
surface.
While spraying, blue
light indicates unit is
working properly.
Remove cap.
Fill approximately
half full in horizontal
position.
Secure fill plug.
Sit bottle on counter
and check water level
with fill line.