00-02-0796 

- 30 - 

2013-04-08 

Set Source Address 

Allows setting the source claim address for the PowerView 

on the CAN Network. Options are 

Auto Claim

 or 

0

 to 

253

Restore All Defaults 

PowerView 

automatically resets

 after the restore defaults 

is complete. 

RESTORING ALL FACTORY DEFAULTS

 

displays when this is selected. 

Clear Machine Hours 

Use this to clear machine hours internal to PowerView 

outside of ECU hours. 

Set Machine Hours 

Machine hours calculate internally when the RPM is greater 

than 50 and the engine is not broadcasting hours. Use this if 

you want to track hours for just the machine. 

Содержание Murphy PowerView PV101-C

Страница 1: ...2013 04 08 00 02 0796 Catalog Section 78 PowerView Model PV101 C User s Guide Version3 2 ...

Страница 2: ......

Страница 3: ...to 1 Up Display Go to 4 Up Display 11 DPF Regen 11 Selecting a Language 13 Stored Codes 14 Engine Configuration 14 Setup 1 Up Display 14 Setup 4 Up Display 17 Service Reminders 20 Select Units 22 Backlight Adjustment 22 Contrast Adjustment 22 Utilities Menu 23 Gage Data 23 Remove All Gages 23 Software Version 23 Fault Conversion 24 Analog Input 25 Engine Speed Control 25 ...

Страница 4: ... Defaults 30 Clear Machine Hours 30 Set Machine Hours 30 Fuel Setpoints 31 DPF Regen Menu ON OFF 31 ENG SPD CTRL Menu ON OFF 32 Faults and Warnings 33 Auxiliary Gage Fault 34 Active Fault Codes 34 Derate Shutdown Codes 35 Acknowledging Fault Codes 36 Troubleshooting 37 Additional Contact Information 42 ...

Страница 5: ...hange our specifications and designs at any time The latest version of this manual can be found at www fwmurphy com Warranty A limited warranty on materials and workmanship is given with this Enovation Controls product A copy of the warranty may be viewed or printed by going to www fwmurphy com warranty ...

Страница 6: ...N OF THIS MURPHY PRODUCT Disconnect all electrical power to the machine Make sure the machine cannot operate during installation Follow all safety warnings of the machine manufacturer Read and follow all installation instructions ...

Страница 7: ...ers and service codes of modern electronic engines and transmissions This guide is intended to help you set up your PowerView display and identify navigation basics and product features The display s simple navigation and powerful features allow you to quickly master the product Additional information can be found on our website at www fwmurphy com pv101 ...

Страница 8: ...when applicable consult engine or transmission manufacturer for SAE J1939 supported parameters Engine RPM Engine hours System voltage Percent engine load at current RPM Coolant temperature Oil pressure Fuel economy Throttle position Engine manifold air temperature Current fuel consumption Transmission oil pressure Transmission oil temperature Transmission gear position Engine configuration paramet...

Страница 9: ...00 02 0796 3 2013 04 08 Faceplate Features ...

Страница 10: ...switches to wear or stick The keys on the keypad perform the following functions Menu Enter or exit menu screens Left Arrow Scroll the screen or move the parameter selection to the left or upward Right Arrow Scroll the screen and move the parameter selection to the right or downward Enter Key Select a menu or parameter or hide view an active fault code ...

Страница 11: ...00 02 0796 5 2013 04 08 Basic Navigation 1 When Menu is pressed the Main menu items display 2 Press the Arrow Keys to move the selection bar to other menu items ...

Страница 12: ...00 02 0796 6 2013 04 08 3 Certain menus have multiple pages Scrolling to the top or bottom item on the current page reveals other menu items on additional pages ...

Страница 13: ...00 02 0796 7 2013 04 08 4 When the desired item is highlighted by the cursor pressing Enter selects that item and displays the corresponding screen ...

Страница 14: ...00 02 0796 8 2013 04 08 First Time Start Up 1 When power is first applied to the display the Murphy logo is displayed NOTE Expect a 20 minute warm up for the display at temperatures of 29o C 20o F ...

Страница 15: ...sting a Wait to Start message this screen will be shown Engine manufacturers typically recommend against starting the engine while this message is broadcasted from the ECU Once the ECU stops broadcasting this message this screen will no longer be displayed ...

Страница 16: ...04 08 3 Once the engine has started the single engine parameter is displayed with the engine RPM Touching the Right Arrow Key displays the coolant temperature The screen can be changed to other parameters by touching Menu ...

Страница 17: ...rphy products are compliant with requirements for U S EPA Emission Standard Tier 4 Interim and EU Emissions Standard Stage IIIB for diesel engines These engines when fitted with a DPF Diesel Particulate Filter can self clean the filter of particulates This self cleaning is known as Regeneration PowerView offers 3 CAN options when DPF REGEN is enabled and available in the engine ECU For more inform...

Страница 18: ...equest for a regen every second for 10 seconds If the engine does not respond PowerView defaults back to Auto DPF Regen You may send the request again or exit without sending a request by touching CANCEL Menu You return to the Main menu 3 INHIBIT DPF REGEN In cases where regen cannot be performed due to restrictions select this to eliminate the possibility of a regen occurring The inhibit lamp dis...

Страница 19: ... Icon PGN SPN Description 64892 3697 High Exhaust Temperature HEST lamp indicates regeneration in process 64892 3703 DPF Particulate Filter Restricted lamp indicates a Regen is needed 64892 3698 DPF Inhibit lamp indicates an inhibited Regen status Selecting a Language From LANGUAGES you may select ENGLISH ESPANOL FRANCAIS ITALIANO or DEUTSCH An asterisk to the right of the language indicates it is...

Страница 20: ...iew the engine s configuration data If the engine does not support this function a No Engine Configuration Data message displays Setup 1 Up Display Press Menu and use the Arrow Keys to highlight SETUP 1 UP DISPLAY then press Enter Three options are available for modification of the 1 Up display 1 Use Defaults This option contains a set of engine parameters Engine Hours Engine RPM System Voltage Ba...

Страница 21: ... Setup highlight and press Enter A list of engine parameters displays NOTE The PV101 must see the parameter being broadcast over J1939 in order to select the parameter from the list To select a parameter use the Arrow Keys to scroll and highlight the parameter then press Enter Selected parameters are indicated by a number to the right of it The numbers represent the order in which the parameters w...

Страница 22: ...CUSTOM SETUP menu 3 Automatic Scan Default is OFF Selecting the AUTOMATIC SCAN ON function will cause the 1 up display to scroll through the selected set of parameters one at a time Once the Use Defaults Custom Setup and Automatic Scan functions have been set touch Menu once to return to the Main menu or twice to display the 1 up display screen ...

Страница 23: ...display include DEF diesel exhaust fluid Level DPF diesel particulate filter active regen status exhaust filter inlet temperature and exhaust filter outlet temperature You can customize each 4 up display with the parameter you define for each quadrant 1 Touch Menu and use the Arrow Keys to highlight SETUP 4 UP DISPLAY and touch Enter 2 To select USE DEFAULTS highlight the option and press Enter A ...

Страница 24: ...s to select which quadrant to edit 7 Once you select a quadrant press Enter and you move to a list of parameters NOTE The PowerView must see the parameter being broadcast over J1939 in order to select the parameter from the list 8 The parameter highlighted is the selected parameter for the screen The number to the right of the parameter indicates in which quadrant it displays ...

Страница 25: ...Arrow Keys to highlight the new parameter to be placed in the selected quadrant Touch Enter 10 Press Menu to return to the SETUP 4 UP CUSTOM SETUP screen 11 The parameter in the selected quadrant has changed to the parameter selected in the previous screen 12 Repeat the parameter selection process until you fill all quadrants ...

Страница 26: ...ew Service Reminders prior to calling Technical Support 1 Use the Arrow Keys to highlight Service Reminders and touch Enter 2 The Service Reminders options display Use the Arrow Keys to select either Reset Reminders or Modify Reminders and then touch Enter 3 If you select Reset Reminders use the Arrow Keys to highlight the Reminder you wish to edit Touch Enter 4 The Reminder name appears at the to...

Страница 27: ...hows Cancel and Save Touch Cancel to discard changes and return to Reminders list 7 Use the right Arrow Key to increment the highlighted number Use the left Arrow Key to move to the next number space 8 Touch Save The Modify Service Reminder screen displays Touch YES to save or NO to return to the Reminders list 9 A modified Reminder displays a at right of Reminder name when successfully completed ...

Страница 28: ...s displayed ENGLISH for Imperial units PSI F METRIC KPA METRIC BAR for IS units kPa Bar C Backlight Adjustment ADJUST BACKLIGHT Use the Arrow Keys to brighten or darken the backlight intensity Contrast Adjustment ADJUST CONTRAST Use the Arrow Keys to lighten or darken the text and graphics ...

Страница 29: ...ew data for optional connected PVA gages When Slave Active is enabled gage data is not available Remove All Gages Reset the gage memory on the PowerView When Slave Active is enabled this function is not available Software Version This screen lists Configuration Firmware Languages and Bootloader versions for this PowerView unit You may need this information if requesting assistance from Technical S...

Страница 30: ...ad one of three other J1939 versions if Version 4 is not used unavailable Most ECU s use Version 4 so adjustment of this menu option is rarely required Upon receiving an unrecognizable fault change to a different J1939 Version in the list If the fault SPN does not change when the version is changed the ECU generating the fault is using Fault Conversion Method 4 If the SPN number does change but is...

Страница 31: ...ouch Enter to reach LOW FUEL screen Use the right Arrow Key to increase and left Arrow Key to decrease the percentage of remaining fuel at which to send a warning The default is 20 NOTE The PowerView accepts optional Murphy fuel sender recommend Model ES2F for fuel level information A custom setup for a non Murphy fuel sender is available For more information see FUEL SETPOINTS page 31 OEM Menu En...

Страница 32: ...rrow Key to increase or left Arrow key to decrease the throttle setting 3 Once the target speed is reached select ENABLE Enter to turn ON the TSC1 throttling control Use Disable to turn throttling control OFF and discard changes NOTE Once enabled Engine Speed Control will stay enabled even through power cycles To turn OFF you must disable the feature from the SPEED CTRL screen ...

Страница 33: ...eric spaces provided Start at the furthest left numeric value and use the Left Arrow Key to increment the number and the Right Arrow Key to move to the next numeric position If the Murphy standard key does not work contact the OEM from whom the engine or machine was purchased If you have access the password is user changeable via the PV101 C Config Tool application The following items are in the O...

Страница 34: ...xiliary gages Highlight your selection and touch Enter 2 If in Slave Active select SERIAL PORT SETUP and touch Enter 3 Scroll through the Serial Port Setup list and make selections for BAUD RATE PARITY DATA BITS and STOP BITS to configure the serial port parameters for your Modbus slave application CANBUS Data Rate Touch Enter to reach the six CANBUS data rates Use the Arrow Keys to highlight your...

Страница 35: ...e PV101 is listening to all devices on the network 2 To change the setting to a specific address press the Arrow Keys to scroll through the selections 0 253 and ALL 3 Once the target address displays press Enter 4 A confirmation screen displays selecting NO Menu returns to the SELECT ENGINE ECU screen Selecting YES Enter stores the selected address and returns to the OEM menu ...

Страница 36: ...atically resets after the restore defaults is complete RESTORING ALL FACTORY DEFAULTS displays when this is selected Clear Machine Hours Use this to clear machine hours internal to PowerView outside of ECU hours Set Machine Hours Machine hours calculate internally when the RPM is greater than 50 and the engine is not broadcasting hours Use this if you want to track hours for just the machine ...

Страница 37: ...must be ON to work with a non Murphy fuel sender Modifying fuel setpoints is a complex process To configure for a Murphy Fuel Sender or program for a non Murphy Sender find document 1110833 PowerView Model PV101 C V3 2 Fuel Sender Calibration on the FW Murphy Web site at www fwmurphy com pv101 DPF Regen Menu ON OFF Highlight and touch Enter to turn this option ON or OFF Turn this option ON to have...

Страница 38: ... 32 2013 04 08 ENG SPD CTRL Menu ON OFF This option must be ON in the OEM Menu for functionality to be available in the Utilities Menu Highlight and touch Enter The Speed Control can be Enabled ON or Disabled OFF ...

Страница 39: ...w provides two means for detecting faults and warnings visual LEDs on the casing Amber in the upper left corner and Red in the upper right corner and fault indicators on the display Visual Indication Amber LED Warning Red LED Derate Shutdown Fault Indicators ...

Страница 40: ...splay will be replaced with a fault message GAGE NOT RESPONDING NOTE A fault can only be cleared by correcting the cause of the condition See Troubleshooting in this document Active Fault Codes When the PowerView receives a fault code from an engine the 1 up or 4 up display is replaced with the active fault codes message See following fault example ...

Страница 41: ...96 35 2013 04 08 Example Active Fault Code screen Derate Shutdown Codes When the PowerView receives a severe fault code from an engine control unit the 1 up or 4 up display is replaced with the SHUTDOWN message ...

Страница 42: ... return to the 1 up or 4 up display touch Enter The display will return to the 1 up or 4 up display but the display will contain the warning or shutdown icon 2 Touch Enter to redisplay the hidden fault Touch Enter once again hides the fault and returns the screen to the 1 up or 4 up display ...

Страница 43: ...o longer be displayed on the PowerView CANBUS FAILURE is displayed The PowerView has not received any valid J1939 CAN messages for at least 30 seconds Check wiring CANBUS termination resistors and Engine ECU address in the OEM Menu TIMEOUT ECU NOT RESPONDING is displayed The PowerView sent a request to the ECU for Stored Fault Code DM2 information and the ECU did not respond to the request This me...

Страница 44: ...ed codes NO GAGE DATA is displayed The PowerView has no record of gages connected to the RS485 bus NO DATA is displayed in place of a parameter value The PowerView has not received data for the selected parameter for at least 5 seconds NOT SUPPORTED is displayed in place of a parameter value This means the data received for this parameter is not valid or not supported ...

Страница 45: ...r has been connected to the analog input One of the 4 UP quadrants is empty No parameter has been selected for display in this quadrant Display is not readable either very dim or very dark The LCD contrast may have been over or under adjusted Press and hold the MENU key for approximately 5 seconds This will reset the LCD contrast setting to factory default PVA Gages not working When PVA Gages are ...

Страница 46: ...00 02 0796 40 2013 04 08 IMPORTANT Before returning your PV101 for Warranty please call our Technical Support team to further trouble shoot any issues 1 918 317 4100 ...

Страница 47: ...00 02 0796 41 2013 04 08 NOTES ...

Страница 48: ...NOTES ...

Страница 49: ...NOTES ...

Страница 50: ...LC This document including textual matter and illustrations is copyright protected by Enovation Controls with all rights reserved 2013 Enovation Controls LLC Other third party product or trade names referenced herein are the property of their respective owners and are used for identification purposes only ...

Страница 51: ...4100 FAX 1 918 317 4124 ipdsales fwmurphy com Web www fwmurphy com FW MURPHY LTD Church Rd Laverstock Salisbury SP1 1QZ UK Phone 44 1722 410055 FAX 44 1722 410088 sales fwmurphy co uk Web www fwmurphy co uk MURPHY ECONTROLS TECHNOLOGIES HANGZHOU CO LTD 77 23 RD Street Hangzhou Economic Technological Development Area Hangzhou Zhejiang 310018 China Phone 86 571 8788 6060 FAX 86 571 8684 8878 apsales...

Страница 52: ...www fwmurphy com PV101 ...

Отзывы: