Installation and Operation Manual
-
SILOTEC
®
8000
Technical Data
Doc.-ID: SILOTEC_11022020_EN
49
A.2
Technical Specifications - Probes
Process gas temperature:
SIL-KES-0001: up
to
100 °C (212 °F)
Immersion depth:
approx. 500 mm
Measuring principle:
Zirconium oxide for O
2
MXP for CO
e
Process gas pressure:
±50 mbar (±0.725 PSIG) to atmospheric pressure
Ambient temperature:
-20 °C to +55 °C (-4 °F to 131 °F) other on request
Reaction time (O
2
):
< 1 s (with test gas)
T90 (O
2
):
< 5 s (with test gas)
Probe material:
stainless steel (SS316)
GRP transmitter with
reduced surface resistance
enclosure
according to EN 60079-0
Protection class:
SIL-KES-0001: IP65, for installation in Zone 22
Power supply:
Through electronic unit
Probe dimensions:
SIL-KES-0001: 640 x 440 x 430 mm (W x H x D)