10020057.xx detectors transmit the state of the dry contact using the frame described in the
document EnOcean Equipment Profiles EEP §D5-00-01 (consultable under
www.enocean.com
).
5.1 Detection:
Each time the dry contact changes state, open to closed or vice-versa, a radio signal is immediately
transmitted. Moreover a signal containing the state of the contact will be sent approximately every
15 minutes.
5.2 Programming and LRN button:
Switch the receiver to learn mode and by pressing the
LRN button placed behind the sensor, initiate the sending
of an association frame.
Where the sensor is located on its base, it must first of all
be unclipped from the base to allow access so that it can
be placed closed to the matched receiver during the
identification or association phase (the receiver having
reduced sensitivity during this phase).
6.1 New or existing installation
• If the receiver functions at a shorter distance relative to the sensor, it is subject to interference or
use outside the transmission range.
• Search the system environment for changes that could cause the interference (for example
movement of metallic cabinets, furniture or partitions).
• Use the sensor or receiver in a more suitable location.
• Clear the receiver and perform a new learn process.
6.2 Limitation of the range of the radio signals
• Transmitter/receiver used close to metallic objects or close to materials containing metallic
elements. Observe a distance of at least 10 cm.
• Humidity in the materials.
• Devices emitting high frequency signals such as audio and video systems, computers, electronic
ballasts or fluorescent tubes. Observe a distance of at least 0.5 m.
6.3 Contacts
E-mail:............................ [email protected]
These products can be marketed and distributed in the countries of the European Union,
Switzerland, Iceland and Norway.
TRI
0
2
SYS
hereby declares that the sensors 10020057.xx
conform to the base requirements and other applicable requirements of the directive 1999/5/CE
referred to as R&TTE.
6. Troubleshooting
ion and initial use
5. Controls and functions
ion and initial use
7. Declaration of conformity
Touche LRN
TOC1314NUEN_1013
1/4
1.1 Use
Sensors
0
2
LINE
10020057.xx are designed to detect any changes in state of equipment having a
dry contact output, normally open (preferred) or normally closed. They are used to connect any
products reporting an On-Off state to the EnOcean protocol where it is either not desired or not
possible to connect them via a wired connection.
The sensor is equipped with a wire that can be connected to the dry contact. The sensor is supplied
by a solar cell and consequently is maintenance-free. As soon as the dry contact changes state
(open to closed or vice-versa) a radio signal is immediately transmitted. Moreover the signal is
retransmitted every 15 minutes.
Before any use, the sensor must be associated with a receiver (maximum 2 sensors). Each sensor
can control an unlimited number of receivers.
Note:
Read the operating manual carefully before initial use.
1.2 Guarantee terms
This operating manual is an integral part of the device and our guarantee terms. It must always be
delivered to the user. We reserve the right to modify the technical design of these devices without
warning.
TRI
0
2
SYS
products are manufactured and their quality checked by making use of the
latest technologies and taking into account the applicable national and international directives. If
nevertheless a fault arises,
TRI
0
2
SYS
undertakes to remedy the default as follows, without
prejudicing the rights of the end customer that arise from the sales contract with his reseller:
If the event of exercising of a legitimate and regular right
TRI
0
2
SYS
, may at its sole discretion,
rectify the device fault or supply a fault-free device. Any claim beyond this and all claims for
consequential damages are excluded.
A legitimate fault exists if the device cannot be used at the time of delivery to the end customer
because of a design or manufacturing defect or if its practical use is severely limited. The guarantee
is void in cases of natural wear and tear, incorrect use, incorrect connection, where the device has
been repaired or external influence. The period of guarantee is 24 months (from the date of
invoicing). French law applies to the regulation of guarantee rights.
1.3 Recycling of the device
To recycle the device, conform to the legislation and standards in force in the country of use.
WARNING! Risk of electric shocks! (See UTE C18-150) Where a connection is
made to an equipment item which is not connected to a very low safety
voltage (TBTS) or via an autonomous power supply, a fault in or lack of
insulation of the latter could cause injuries in the event of accidental contact;
this includes contact with our sensor! All work on the mains supply network
and the connected device must only be carried out by authorised professional technicians.
1. General
TRI
0
2
SYS
sarl
– 8 grande rue le village
21160 FLAVIGNEROT
2. Safety
!
Installation and operating manual
Wired dry contact sensor
Ref. 10020057.xx
EN