2.3
Interface pin layout
Figure 3 below shows the pin out and external interfaces of PTM 535 as seen from the top
(component side). Items marked in green are on the component side while items in grey
are on the bottom side.
In addition to the 16 boundary contacts, PTM 535 provides the following contact points:
◼
Meander contact A0
◼
Meander contact A1
◼
Connection for whip antenna RF_WHIP
◼
Footprint for LEARN button (connecting VCC and SEC)
◼
AC1 / AC2 power supply connection to ECO 200 harvester
(two contact pairs at the PCB bottom side to support different ECO 200 orientation)
Figure 3
–
PTM 535 pin-out and external interfaces