background image

To change the lens:

1.  If the sensor is mounted, press the top tab and remove it 

from the mounting plate.

2.  Unscrew the front cover screw on the back at the bottom 

and remove the front cover. 

 

 

 

 

 

 

 

 

3.  Remove the installed lens by  

gently squeezing it to ease one  

side out of its groove, and then  

the other.

4.  Insert the lens you want to use  

by aligning the notch with the  

top on the front cover. Orient the  

smooth side facing out, and the  

textured side facing the sensor.

5.  Hold both edges of the lens, flex it gently and push until it 

pops into the grooves. Make sure the edges are flush. 

NOTE: If the lens is out of  

position, the sensor will not  

detect activity properly.

6.  Replace the top edge of the  

front cover and then close it  

on the sensor.

7.  Replace the bottom screw  

and remount sensor on the plate.

Installing Supplemental Battery (optional)

If light levels are very low where the sensor is installed, auxiliary 

battery power (CR2032) can be used to supplement the solar 

energy harvester.
1.  Remove the sensor from the  

mounting plate.

2.  Unsnap sensor cover and  

identify the battery holder  

on the circuit board.

3.  Insert the battery under the  

clip with the positive pole (+)  

up and press it in place.

4.  Replace cover and remount  

the sensor on the wall.

 

Troubleshooting

Problem

Solution Checklist

Sensor does not 

generate a wireless 

message

 

Verify the LED blinks when motion is detected 

during a walk test

 

Verify the solar cell is charged properly

Sensor is activated 

when there is noth-

ing to detect

 

Verify there is 4 ft. (1.2 m) clearance from heat 

sources that may disturb sensing

 

Reduce sensitivity setting by moving the PIR 

sensitivity switch on the back to low (the left-

hand position)

Linked device does 

not respond to 

wireless messages

 

Check for environment or range issues

 

Verify the device is linked

 

Check the transceiver connection and the wir-

ing for errors

 

Check if appropriate devices are linked accord-

ing to good system planning

 
 

FCC SZV-EOSW01 

  

IC 5713A-EOSW01

This device complies with part 15 of the FCC rules and Industry Canada ICES-003. Operation 

is subject to the following two conditions: (1) This device may not cause harmful interference, 

and (2) this device must accept any interference received, including interference that may 

cause undesired operation.
IMPORTANT! Any changes or modifications not expressly approved by the party responsible 

for compliance could void the user’s authority to operate this equipment. 
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio 

exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne 

doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage 

radioélectrique subi, meme si le brouillage est susceptible d’en compromettre le fonc-

tionnement. 
IMPORTANT! Tous les changements ou modifications pas expressément approuvés par la 

partie responsable de la conformité ont pu vider l’autorité de l’utilisateur pour actioner cet 

équipment. 

Limited Warranty

Subject to the other terms of this warranty, the manufacturer warrants you the original 

purchaser that this product will be free from defects in material and workmanship for one year 

from the date of your purchase of the product. During that period, if the product does not 

comply with this limited warranty, the manufacturer will, at its discretion, repair or replace the 

product. Repair or replacement is your sole remedy under this or any other warranty of the 

product, whether express or implied.
Coverage Limitations. This limited warranty extends only to the original purchaser and is 

not transferable. This limited warranty expressly excludes any defects or damages resulting 

from any product installed improperly or in an improper environment, overloaded, misused, 

opened, abused, or altered in any manner.
To obtain warranty service - return the product, a description of the problem, together with 

your proof of purchase, securely packaged and with postage prepaid, to the manufacturer.
You may be required to provide other information or evidence of the defect. Any returned 

product that is replaced becomes the property of thye manufacturer.
Implied Warranties. TO THE EXTENT PERMITTED BY LAW, ANY IMPLIED WARRANTIES, IN-

CLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, 

ARE LIMITED TO THE SAME DURATION AS THIS EXPRESS WARRANTY. Some states do not 

allow limitations on how long an implied warranty lasts, so the above limitation may not apply 

to you. NO OTHER EXPRESS WARRANTY HAS BEEN MADE OR WILL BE MADE BY THE MANU-

FACTURER WITH RESPECT TO THIS PRODUCT.
Limitation of Liability. THE MANUFACTURER SHALL NOT BE RESPONSIBLE FOR SPECIAL, 

INCIDENTAL OR CONSEQUENTIAL DAMAGES SUCH AS THE COST OF LABOR FOR REMOVAL 

OR REINSTALLATION OF THE PRODUCT, WHETHER ARISING OUT OF BREACH OF WARRANTY, 

BREACH OF CONTRACT, TORT, OR OTHERWISE. Some states do not allow the exclusion of inci-

dental or consequential damages, so the above exclusion and limitation may not apply to you.
This limited warranty gives you specific legal rights, and you also may have other rights which 

vary from state to state. In Canada, the above provisions are not intended to operate where 

prohibited by law and do not preclude the operation of any applicable provisional consumer 

protection statute which in certain circumstances may extend the express warranties herein.

Occupancy Sensor – Wall Mounted • Installation Guide

Page 4

Содержание EOSW

Страница 1: ...0 lux for 30 transmissions hour 100 lux for 60 transmissions hour Charge Time before Linking 2 minutes 50 lux Charge Time for Full Charge 3 hours 200 lux after startup 6 hours 200 lux cold start Operating Life in Dark ness after full charge 48 hours EEP EnOcean Equipment Profile A05 07 01 Heartbeat 2 12 mins randomized Dimensions 5 83 L x 2 52 W x 1 8 D 148 mm x 64 mm x 45 7 mm Weight 4 09 oz 116 ...

Страница 2: ...ong Range Coverage 16 ft 0 16 ft 8 ft 8 ft Top View 27 77 21 5 14 6 5 center line Side View 6 8 ft 2 1 m 3 ft 1 m 7 ft 2 2 m 10 ft 3 m 35 ft 10 7 m 60 ft 18 3 m 100 ft 30 5 m Installing The mounting plate can be installed flush to the wall or angled in a corner NOTE It may be easier to link the sensor before it is mounted on the wall See the Linking section 1 Remove the mounting plate from the sen...

Страница 3: ...e transceiver controller installation guides to complete the linking process Testing the Sensor Before starting a test ensure the sensor s energy storage is fully charged by placing it under bright light at least 200 lux for 20 minutes or insert a battery for 5 minutes If a battery is used to charge the sensor for a light test ensure it is removed to get an accurate light measurement A test mode w...

Страница 4: ...oit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi meme si le brouillage est susceptible d en compromettre le fonc tionnement IMPORTANT Tous les changements ou modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l autorité de l utilisateur pour actioner cet équipment Limited Warranty Subjec...