USER MANUAL
EMDC
–
ENOCEAN MOTION DETECTOR AND LIGHT LEVEL SENSOR
© 2020 EnOcean | www.enocean.com
EMDC User Manual | v1.0 | March 2020 | Page 64/75
9.5.21
AMBIENT_LIGHT_TEST_RESULT
If EMDC has executed an ambient light test as described in chapter 2.5.5 then the result
(the measured average light level at the solar cell) will be stored in the ILLUMINA-
TION_TEST_RESULT register shown in Figure 44 below.
AMBIENT_LIGHT_TEST_RESULT (Default Setting: 0x0000)
Bit 15
Bit 14
…
Bit 1
Bit 0
AMBIENT LIGHT TEST RESULT
Figure 44
–
AMBIENT_LIGHT_TEST_RESULT register
The field AMBIENT LIGHT TEST RESULT will provide the measured average light level ex-
pressed as integer value between 1 lux and 65535 lux. This field will be set to zero if the
test is in progress or has not been executed yet.
9.6
USER DATA
The USER DATA area allows the user to read and write up to 64 byte of data after entering
the correct PIN code. Typical use cases include storing information about the configuration
or the installation of the device (by whom, when, what).
EMDC does not use this area and does not interpret its content in any way.