QUICK START GUIDE
The Well Watch 310 Display Unit is nearly ready to go right out of the box. Follow the
few steps below to connect to the Well Watch 660. To learn about the more advanced
features continue reading the operation section of this manual.
1.
Apply power
. Connect the power adapter to the Display unit, then plug the
power adapter into a wall outlet. The display should come on and briefly
show the model and version number.
2.
Select Well Watch
. Press MENU. Then DOWN so display reads Well Watch
Setup. Then press ENTER, so the display reads Connection. The unit is set
to communicate using a wireless connection by default. If a wired connection
will be used, press ENTER so the display flashes. Then press UP or DOWN
to select RS485. Press ENTER again so the display stops flashing.
3.
Select Address
. Press DOWN to see Address. The default address set in
the Well Watch and the display unit is 6. If the address in the Well Watch has
been changed, then press ENTER so the address flashes, UP or DOWN to
make the address match the Well Watch, then ENTER again to stop the
flash.
4.
Select Channel
. Press DOWN to see Channel. The default channel set in
the Well Watch and the display unit is 11. If the channel in the Well Watch
has been changed, then press ENTER so the channel flashes, UP or DOWN
to make the channel match the Well Watch, then ENTER again to stop the
flash.
5.
Display
. Press HOME to return to the default screen and display the
information from the Well Watch. Press UP or DOWN to show additional
information.
We encourage you to read the frequently asked questions section. They really are
frequently asked. Also, visit our website
www.enoscientific.com
for the latest manual
and installation tips.