background image

1. Overview 

Thank you for purchasing the ennoLogic eA990R anemometer, 
a high quality instrument which measures 8 parameters:

 

 

Wind Speed (mph, m/s, ft/min, knots, km/h) 

 

Wind Chill (°C / °F) 

 

Air Temperature (°C / °F) 

 

Humidity (%) 

 

Heat Index (°C / °F) 

 

Dew Point ((°C / °F) 

 

Barometric Pressure (hPa, mbar, inHg) 

 

Pressure & Relative Altitude (m, ft) 

 

The eA990R anemometer comes with many powerful features 

including the following: 

 

LCD with White Backlight 

 

Beaufort Scale 

 

Maximum, Minimum, and Average Reading Display 

 

Hold Function 

 

Rechargeable Li-Ion battery 

 

Low Battery Indicator 

 

Auto Power Off (with override option) 

 

Calibration Function 

 

CE Certified & RoHS Compliant 

 

Important: 

This meter is accurate at low and mid-range air speeds. 

Consistent use at very high speeds, e.g. from the window of a fast 

moving car will damage the impeller’s bearing and reduce accuracy. 

 

Содержание eA990R

Страница 1: ...eA990R Digital Anemometer User Manual...

Страница 2: ...A990R anemometer comes with many powerful features including the following LCD with White Backlight Beaufort Scale Maximum Minimum and Average Reading Display Hold Function Rechargeable Li Ion battery...

Страница 3: ...1 oF 0 to 65 mph 49 to 50 0 1 1 8 Temperature oC 29 to 70 0 1 1 oF 20 to 158 0 1 1 8 Relative Humidity RH 0 to 100 0 1 2 Heat Index oC 0 to 100 RH 21 1 to 54 4 0 1 2 oF 0 to 100 RH 70 to 130 0 1 3 6...

Страница 4: ...14oF to 140oF 10oC to 60oC Storage Humidity 10 to 75 RH Battery Lithium Polymer 300mAh rechargeable Current Consumption 11 mA 14 mA with backlight on Size 4 5 x 1 8 x 1 115 45 25 mm Weight 2 5oz 70g P...

Страница 5: ...second to turn the anemometer off After 5 minutes without any operation the anemometer will power off automatically To disable Auto Power Off hold the Backlight button down while turning the unit on...

Страница 6: ...de Changing the Measurement Units In any measurement parameter mode briefly press the Units button to change the measurement unit displayed For example in wind speed mode choose between mph m s ft min...

Страница 7: ...meter is turned off Beaufort Scale The Beaufort scale categorizes wind speed according to observed conditions at sea or on land 0 Calm 1mph 1 Light air 1 3mph 2 Light breeze 4 7mph 3 Gentle breeze 8 1...

Страница 8: ...n for more than 2 seconds This is handy for measuring air flow in difficult situations To track maximum minimum and average readings simply press the Max button briefly to cycle through them For avera...

Страница 9: ...ir feels colder than it is because of the chilling effect of the wind Wind Chill is expressed as a temperature which is typically lower than the air temperature Wind chill temperature is valid only fo...

Страница 10: ...h it Temperature response depends upon air flow through the unit due to the location of the temperature sensor inside the unit Response may be slow at zero air flow 5 to 10 minutes but typically only...

Страница 11: ...n the anemometer and press the Mode button 3 times The display will show RH below the value of relative humidity Relative humidity and temperature are measured by the same sensor This sensor is locate...

Страница 12: ...rspiration which removes heat from the body by evaporation High relative humidity slows evaporation which slows down heat removal from the body This causes the feeling of being overheated Heat index i...

Страница 13: ...r is evaporating Below the dew point water will begin to condense on surfaces forming dew or particles in the air forming clouds and fog To measure dew point power on the anemometer and press the Mode...

Страница 14: ...s in sea level pressure are quite small the highest and lowest sea level pressures ever recorded are 32 01 inHg in Siberia and 25 9 inHg during a typhoon in the South Pacific To measure barometric pre...

Страница 15: ...Plane The Standard Datum Plane is a theoretical level where the weight of the atmosphere is 29 92 inches of mercury As atmospheric pressure changes the Standard Datum Plane may be below at or above s...

Страница 16: ...e between your newly set zero reference altitude and your current position To change back to Pressure Altitude press and hold the Units button again for five seconds Calibrating Your Anemometer NOTE D...

Страница 17: ...d the Units button down while turning on the anemometer Calibrating Barometric Pressure To calibrate barometric pressure use a reliable instrument or trusted source for barometric and altitude reading...

Страница 18: ...on the display shows 5 the code for altitude Press the Power button The display will now show a value that is actually the default pressure altitude at the current atmospheric pressure in this case 00...

Страница 19: ...ile hiking or climbing for instance Battery Replacement This anemometer uses a rechargeable 3 7V Lithium Polymer battery that is built in and is not intended to be replaced by the user This battery ca...

Страница 20: ...Digital Anemometer ennoLogic eA990R Made in China User Manual Version 1 2 Revised 06 11 2020 2020 ennoLogic All rights reserved PO Box 25207 Eugene OR 97402 U S A http ennologic com...