background image

-3-

1199135-A02-B   07/09/2012

Check the distance between the  

walls to ensure that the Door and

Return are within the maximum and 

minimum enclosure tolerances.

1

Shower base MUST be installed 

level.

3

Select preferred shower door 

opening and Return position.

4

Position Wall Retainer Profiles 

against shower walls, resting on 

the shower base sill. 

Door wall retainer must have the  

fixing holes towards the inside of 

shower.

5

DOOR SIDE

RETURN SIDE

10 mm

10 mm

These Profiles should be located 

10mm from the front edge of shower 

base.

Check vertical with spirit level and 

mark fixing holes.
ENSURE WALL RETAINER PRO-

FILES ARE PLUMB.

 

DOOR SIDE

RETURN SIDE

TYPE

DOOR ADJUSTMENT (mm)

              MIN                  MAX

900x900
1000x1000

850

892

950

982

TYPE

DOOR ADJUSTMENT (mm)

              MIN                  MAX

900x900
1000x1000

854

875

960

981

A

B

It is recommended that the waste 

outlet be ‘taped over’ to avoid the

loss of any components during 

installation.

2

Содержание TRADE SERIES

Страница 1: ...ANT REQUIRED TO COMPLETE THIS INSTALLATION not supplied I M P O R T A N T R E A D A L L I N S T R U C T I O N S C A R E F U L L Y B E F O R E S T A R T I N G T H E I N S T A L L A T I O N T H I S W I L L E N S U R E Y O U O B T A I N T H E B E S T P O S S I B L E R E S U L T S TOOLS REQUIRED Level Tape Pencil Phillips screwdriver Ruler Drill Caulking gun NOTE Tapware not included Supplied handles ...

Страница 2: ... 2 1199135 A02 B 07 09 2012 Fitting Instructions DOOR AND RETURN NOTE SHOWER TRAY MUST BE INSTALLED AS DETAILED ON SUPPLIED INSTRUCTIONS ...

Страница 3: ... wall retainer must have the fixing holes towards the inside of shower 5 DOOR SIDE RETURN SIDE 10 mm 10 mm These Profiles should be located 10mm from the front edge of shower base Check vertical with spirit level and mark fixing holes ENSURE WALL RETAINER PRO FILES ARE PLUMB DOOR SIDE RETURN SIDE TYPE DOOR ADJUSTMENT mm MIN MAX 900x900 1000x1000 850 892 950 982 TYPE DOOR ADJUSTMENT mm MIN MAX 900x...

Страница 4: ...ssembly to be fitted 10 Fit Door Assembly into Wall Retainer Profile then re positon Corner Profile and Return Panel to Door Assembly 11 Re align 90O Profile to pre determined corner position 12 13a b Note If Screwing into backing board only use appropriate wall anchors in the wall CAUTION BEFORE DRILLING HOLES ENSURE THERE ARE NO ELECTRICAL CABLES OR WATER PIPES BEHIND WALLS CAUTION We recommend ...

Страница 5: ...and retainer bracket are handed Push drip seal firmly back onto glass and pull into contact with door edge extrusion Clamp in place using the bracket and No 6 screw 18 Fit handles following instructions with handle 19 20 NOTE This is an important part of the installation procedure and your careful attention at this stage will ensure that you will obtain the best possible results DO NOT PROCEED TO ...

Страница 6: ...peration Fit screw screw caps and remove tape Fit long seal to hinge edge of glass Flap faces towards glass Push down to butt against bottom seal Trim to 5mm below top of glass 23 21 Position Return Panel PVC gasket by pushing outside leg into both Wall Retainer and Corner Post It should snap into place Now push the inside leg into place 22 RETURN WALL RETAINER DOOR WALL RETAIN 90O CORNER POST Ins...

Страница 7: ...th CAUTION Avoid contact with skin eyes and mouth and avoid breathing vapour If in eyes immediately flush with water If irritation persists seek medical attention Keep out of reach of children IMPORTANT SIKASIL NG SEALANT SHOULD BE AP PLIED TO ALL OUTSIDE JOINTS DO NOT SEAL FROM INSIDE 2a Seal full height the joint between the Walls and the Wall Retainers b Seal joint between the Door Sill the Ret...

Отзывы: