Page | 5
SPECIFICATIONS
Heating
Specifications
•
Maximum
Burn
Time**
..................................................................................
14
hours
•
Approximate
Square
Footage
Heated***
....................................................
2400
sq.
ft.
•
Flue
Collar
..................................................................................................
6.0
in.
round
Dimensions
(Inches)
*
Specifications
are
approximate.
Be
sure
to
locate
your
stove
in
the
installation
area
before
installing
pipe,
etc.
EPA
and
Safety
Compliance
Specifications
EPA
Compliance
Status
…….......
Certified
to
comply
with
2020
particulate
emission
standards
using
cord
wood.
EPA
Test
Standard
………………………………..
ASTM
E3053
‐
17,
EPA
Alt
125,
CSA
B415.1
‐
10
Particulate
Emissions
……………………………
2.0
grams/hr
CO
Emissions
………………………….…………….
2.3
grams/min
Heat
Output
Range
……………………………..
16000
–
39600
Btu/hr
Efficiency……
………………………….……………
70%
(HHV)
Certified
To
…………………………….……………
UL
1482
‐
2011(R2015)
and
ULC
‐
S627
‐
00(R2016)
Notes
for
this
unit:
Product
may
vary
slightly
from
diagrams.
Clearances
are
the
minimum
for
this
unit
and
may
need
to
be
increased
to
have
proper
vent
clearances.
Follow
all
venting
manufacturer
clearances
and
local
codes.
***
‐
The
maximum
heating
capacity
of
this
unit
can
vary
greatly
based
on
climate,
construction
style,
insulation
and
a
myriad
of
other
factors.
Use
this
information
in
conjunction
with
a
BTU
loss
calculation
for
your
home
to
determine
if
this
unit
will
be
sufficient
for
your
needs.
24
‐
in.
Wide
31.25
‐
in.
Deep
30
‐
in.
High