Page | 23
We recommend that you leave the thermostat at the factory settings until the unit
has been burned for at least 30 days.
FIBER BOARD
THIS WOOD HEATER UTILIZES RECENT TECHNOLOGY, WHICH INCLUDES CERAMIC
FIBER BOARD THAT IS LOCATED IN THE FIREBOX, AND RESTS ON TOP OF FOUR
STAINLESS STEEL TUBES.
DO NOT REMOVE THIS CERAMIC FIBER BOARD!!!
IT IS A NECESSARY COMPONENT OF THE FIREBOX.
ALSO PLEASE NOTE: THE CERAMIC FIBER BOARD MAY BECOME LOOSE DURING INITIAL
SHIPPING. BE SURE IT IS LYING FLAT, ON TOP OF THE STAINLESS STEEL TUBES, AND
PUSHED ALL THE WAY TO THE BACK OF THE UNIT, WITH NO GAPS BETWEEN IT AND
THE BACK WALL OF THE STOVE.
MAINTENANCE: This unit is equipped with a ceramic Fiber Board ceiling baffle (two
pieces). After extensive use, the board should be removed and cleaned.
The following steps should be followed for cleaning or replacement:
1. Ensure the appliance is not in operation and is completely cooled down.
2. There is one screw in each stainless steel tube holder, located in the fire box
ceiling. Remove the screws from the front and middle tube holders.
3. Shift each loose tube to the right, so that one end comes completely out of the
socket. Drop the end down and pull it out by pulling it back to the left.
4. Drop the first board down and push the left corner to the top left. Bring the right
corner down to the bottom right of your door opening, and pull the right side out
first. Repeat for the second board piece.
5. Vacuum the boards off and blow the carbon out of the tubes, if there is any build-
up.
6. Re-install the boards and tubes, reversing the same method they were removed.
Содержание 28-4000
Страница 24: ...Page 24 Placement of Stainless Steel Burner Tubes for all 28 4000 50 SHW40 50 TRW40 stove models...
Страница 33: ...Page 33...
Страница 69: ...Page 33...