background image

C. Glass 

Windows 

 
This unit is manufactured with high temperature ceramic glass, and substitute materials should not be used. 
This stove should not be operated if the glass is cracked, broken or removed.

 

       The  glass/frame  assembly  shall  be  replaced  as a complete unit as supplied by the manufacturer. The 
replacement of the glass should done by a licensed or qualified service person. This stove has a middle and two 
side glasses that mount inside the door frame. The glass can be changed by removing the window bracket that 
is located in the bottom inside of the door frame. The bracket can be removed by raising it up and removing it 
through the small channel located on the lower left side of the door frame. The new glass with gasket can then 
be placed in the proper space and the channel snapped back into place. The replacement glass is designed for 
our units only and can be ordered by calling (Parts Orders Only: 1-800-516-3636). 

     

When the stove is first started, the glass will fog up with condensation from the combustion process. The 

condensation will evaporate and disappear as the glass and stove reach full operating temperature, which will 
usually take two to three minutes. 
      If you happen to see a grey film or haze forming on the inside of the glass, it should be removed 
immediately; this could be from the logs not being located properly and too much flame hitting them. The haze 
can be removed in the early stages, but is permanent if left on too long. The logs should be all the way to the 
back and left inside the stove. 
 

WARNING: DO NOT USE ABRASIVE CLEANERS. ALLOW THE UNIT TO COOL DOWN BEFORE 

CLEANING THE GLASS. DO NOT ABUSE THE GLASS BY SLAMMING THE DOOR OR 
STRIKING THE GLASS. 

 

D.  Valve and Burner Controls 

 

1) Variable Heat Input Controls

 

 

 

 

On the gas valve, to the left of the green or black gas control valve knob is another control. This is the 

variable heat input control that continually varies the gas going into the stove from low to high. The high setting 
allows the maximum amount of gas to enter your stove, and is used for cold winter nights or when you desire to 
heat a larger space; the low setting may be used during the spring and fall months when not as much heat is 
required. The low setting gives approximately 50% of the heat as compared to the high setting. 

 
2) Air Shutter Adjustment on the Burner Tube 
 

     The air shutter is an adjustment on the burner tube. Its purpose is to control the amount of air that enters the 
burner tube. In concept, opening the shutter permits more air to enter the tube and causes the flames on the 
main burner to be bluer and burn cleaner. Closing the shutter has the opposite effect, and causes the flame to 
burn orange and dirtier. 

Note: Only a qualified service technician should make Air Shutter adjustments. 

 
E.   Seasonal Shut-down 
 

     At the end of the season, the stove should be shutdown completely, which will conserve gas and save you 
money. 
     First, move the thermostat control or lever to the “OFF” position.  
     Then, shut off the gas to the main burner by turning the gas valve control knob fully clockwise 

 

to the “OFF” 

position. 

 

F.  Lighting the Heater During Regular Use 
 
     

Simply turn up the switch on the wall thermostat to the desired temperature. If the thermostat temperature is 

greater than the room temperature, the heater will come on immediately. If the thermostat temperature is less 
than the room temperature, the main burner will not come on until the temperature falls below the thermostat 
setting. 

 

G.  Shut-down During Regular Use 

Содержание 26-GBVLP

Страница 1: ...Y A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE REFER TO AND SAVE THIS MANUAL CONSULT A QUALIFIED INSTALLER SERVICE AGENCY OR YOUR GAS COMPANY BEFORE INSTALLATION Rev 5 06 WHAT TO DO IF YOU SMELL GAS DO NOT TRY TO LIGHT ANY APPLIANCE OPEN ALL WINDOWS AND EXTINGUISH ANY OPEN FLAME DO NOT TOUCH ANY ELECTRICAL SWITCH DO NOT USE THE TELEPHONE IN YOUR BUILDING C...

Страница 2: ...g guide on our web site we have always tried to help our customers stay heat ready especially when oil and electricity prices continue to skyrocket Please look at our vast Help section on our web site and call our Customer Service department at 800 245 6489 if you need any help with your unit We are nearly always able to help walk you through any repairs problems or questions you may have PLEASE N...

Страница 3: ...LECTRICAL CODE WHILE SERVICING THIS UNIT ALL ELECTRICITY AND GAS SHOULD BE COMPLETELY SHUT OFF ALWAYS BE SURE THE STOVE IS COMPLETELY COOLED DOWN PRIOR TO DOING ANY TYPE OF SERVICE WORK THIS STOVE HAS A STANDING PILOT LIGHT THAT IS LIT USING A PIEZO ELECTRIC SPARK GENERATOR AS DESCRIBED IN OTHER PARTS OF THIS MANUAL NEVER ATTEMPT TO LIGHT THE PILOT OR MAIN BURNER WITH A MATCH OR LIGHTER IF THE PIL...

Страница 4: ...ia Ignition Piezo electric pilot Piezo electric pilot Actual weight 161 lbs 161 lbs Shipping weight 185 lbs 185 lbs SECTION I FLUE SYSTEM FOR VENTED GAS FIREPLACE HEATER A Installation of a New System See Installation Drawings at the end of this Manual This vented gas fireplace heater must be connected to four inch 4 diameter Type B 1 gas pipe This product is manufactured and certified to NFPA 54 ...

Страница 5: ...hermostat from the interior of the stove Note Do not remove the ceramic logs If you do so by mistake follow the guidelines below for proper placement of the logs B Log Placement The logs are in the proper position when the unit leaves the plant However during the shipping of the unit the assembly can become misarranged Check to be sure the logs are still located in the provided slot behind the fro...

Страница 6: ...ations above 610 1370 meters the orifice size for natural gas is 35 DMS and for liquid propane the size is 52 DMS per CAN CGA 2 17 tests current edition For high altitude installations consult the local gas distributor or the authority having jurisdiction for proper rating methods If the installer must convert the unit to adjust for varying altitudes the information sticker must be filled out and ...

Страница 7: ...nstalled the pipe will completely cover the flue collar The pipe will be marked with arrows and all pipe should be installed with these pointing up or away from the unit These are called direction of flow markings and should be oriented properly See Installation Drawings at the end of this Manual B Thermostat Your stove comes supplied with a wall thermostat that controls the temperature of the uni...

Страница 8: ...onnector pipe and chimney is unobstructed Be sure the door is properly sealed When installing the blower check all connections to avoid electrical shock Open the gas valve access door to get to the valve this will also expose the instructions FOR YOUR SAFETY READ BEFORE LIGHTING 1 This appliance is equipped with a manual piezoelectric ignition device Do not try to light the pilot by hand 2 Before ...

Страница 9: ...tely 30 60 seconds Release the gas valve control knob and it will pop out If the knob does not pop up when released stop and immediately call your service technician or gas supplier The pilot is now lit 11 For the very first lighting it may take several attempts to purge air from the gas line If pilot ignition does not occur or the pilot goes out repeat steps 9 and 10 12 Turn the gas valve control...

Страница 10: ... Flame Size Firebox Flame Size B Smoke and Odor There will be some visible smoke and some odors coming from the stove with the first few fires These are caused by the burning of binders from the logs and brick fiberboard oils from the manufacturing process and curing of the painted surface of the stove This off gassing will cease after a few fires however it is a good idea to open some windows and...

Страница 11: ... GLASS BY SLAMMING THE DOOR OR STRIKING THE GLASS D Valve and Burner Controls 1 Variable Heat Input Controls On the gas valve to the left of the green or black gas control valve knob is another control This is the variable heat input control that continually varies the gas going into the stove from low to high The high setting allows the maximum amount of gas to enter your stove and is used for co...

Страница 12: ...ith a glass cleaner but we advise never to use an abrasive cleaner for this operation C Check the venting system at the beginning and the end of each heating season to be sure it is connected properly and no blockages have occurred A qualified technician should do this REPLACEMENT PARTS DESCRIPTION PART NUMBER Front Glass AC G14 Side Glass AC G13 4 Blank Flange CA 3029 4 Flue Collar CA 3031 Front ...

Страница 13: ...d by the flame flame directly impinges upon it Wiring is loose in system Tighten any loose wires Defective thermopile Replace thermopile 3 No ignition to burner Gas is off Turn on gas Pilot is off Light by instructions Thermostat is set too low Move to higher setting Thermostat is defective Connect the 2 thermostat wires together If the unit lights the thermostat is bad replace it 4 Carbon deposit...

Страница 14: ...Installation Drawings Through the Ceiling and Through the Wall Note When running double walled pipe up the side of home you must build a chase around the chimney pipe ...

Страница 15: ...ause of an accident improper handling improper operation improper installation shipping damage abuse or unauthorized repair made or attempted to be made Purchaser must give notice of claim of defect within the warranty period and pay any transportation expense to and from a service center designated by the factory for service The dealer from whom the stove was purchased or the factory will perform...

Страница 16: ......

Страница 17: ...e Date _________________ Purchase Price ____________________ Serial Number _____________________ Mfg Date ______________________ How did you first hear about our product please check one ___ Word of Mouth ___ Burn Trailer Demonstration ___ Internet Other ____________________________________________________ Where did you receive information about our product please check one ___ Rec d info via phon...

Отзывы: