Technical Data
Rated power: 60 W
Power Outlet Impedances : 8Z, 16Z
Minimum Input level: - 45 dB
Maximum Input Level: + 1,5 dB
Effects loop: SEND - 10 dB (average), 0 dB (max.)
RETURN + 3 dB (max.)
LINE output: + 6 dB (at 1kHz!)
Levels are based on 0db => 1 V eff, measured at 1kHz.
Tubes: V1 -> ECC83/7025 F.Q.
V2, V3 -> ECC83/12AX7 selected
V4 -> ECC83/12AX7 standard
V5, V6 -> EL 34 /6CA7matched sets
Fuses: AC mains: 230 Volts 100 and 120Volts
external 1,25 AM 2,5 AM (medium)
internal 1,6 AT 3,15 AT (slow)
Power tubes (ECS): 2 x 160 mAM
Dimensions: (l x h x d) 60 x 24 x 25 cm (23,6 x 9,5 x 9,8 ")
Weight: app. 15 kg
We reserve the right to make unannouced technical upgrades.
Tube array:
E C S ( Emergency Circuit System):
This circuit ensures the amplifier does not shut down completely when a single power tube fails. The amp
continues to perform at approx. 1/3 of the rated power, depending on the type of defect.
Gas developing in the power tubes can cause a momentary short circuit. The fuse activates, but the amp is
not shut down! Often the tube absorbs the developed gas, and is operable after a short circuit. Sometimes
the problem can be rectified by replacing the fuse, but if the new fuse activates as well, the defective
power tube needs to be replaced.
8
V 1
V 2
V 3
V 4
V 5
V 6
Output
Transformer
Power
Transformer