background image

FX Loop II Balance

FX mix control for FX Loop II. When the knob is set to Dry, the amp signal is routed through with no proces-
sed signal (0% wet balance) added to the mix. Twist the knob clockwise to blend in the processed signal 
(parallel/passive, wet balance 1-99%, depending on knob position). When the knob arrives at the Effect 
position, only the wet signal (that is, the processed signal generated by the connected effect device) is 
patched to the power amp (serial, 100% wet). 

NOTE: 

Set this knob to Dry when the FX Loop is not in use! Settings between 9 and 3 o‘clock position reduce 

the signal level. In the event of contact corrosion of the FX Return socket, volume fluctuations may occur.

Power Tube Monitor

This red LED lights up to indicate one of the internal power tube fuses has blown. You can continue playing, 
but the amp‘s performance will be diminished. Normally the loss of a power tube results in an unbalanced 
signal. Be sure to have a specialist look over the power amp as soon as possible; the fuse probably blew 
because of a defective power tube. Once a fuse has blown, it must be replaced by a new fuse. 

Line Output – 0 dB Poweramp Signal

This port taps the power amp‘s output to provide a line out signal configured at a level of about 0 dB. The 
frequency response is identical to that of the power amp output signal. In other words, its frequency res-
ponse is not compensated or corrected. You can feed this signal to another linear power amp. Another op-
tion is to patch it through an outboard filter to emulate a speaker, or for example into the ENGL CABLOADER 
(IR-Loader with an integrated microphone and poweramp simulation), and feed this externally processed 
signal to a recording device or PA system.

Poweramp Output, 4 Ohms Parallel

4 ohms speaker output jacks, internal connected parallel.

Poweramp Output, 8 Ohms Parallel

8 ohms speaker output jacks, internal connected parallel.

Poweramp Output, 16 Ohms

16 ohms speaker output jack.

Содержание E610II

Страница 1: ...E610II Savage 120 II E630II Savage 60 II Operator s Manual...

Страница 2: ...nce some of the proven features to a top notch level Furt hermore I equipped these superb amps with a few new features like two mid range control knobs for main channel I that gives the player additio...

Страница 3: ...tivated the level in Channels Clean and Crunch I gets boosted for approx 10 dB The level in Channels Crunch II and Lead I gets boosted for approx 4 dB A TIP FROM THE DESIGNER use this feature to reduc...

Страница 4: ...und option can also be switched via MIDI program change MIDI Controller 27 or the ENGL Z9 The red LED above the button lights up to indicate when CONTOUR is activated A TIP FROM THE DESIGNER in a cert...

Страница 5: ...D BOLD you will boost the low mids markedly which can have a huge effect across the full frequency spectrum of some sounds These two knobs different sound shaping properties together with the Preshape...

Страница 6: ...ight those cherished tubes are the culprits The Noise Gate is a tool that lets you silence this noise during breaks by way of signal mute circuit Note that electric guitars pick up interference signal...

Страница 7: ...ob determines the power amp s high frequency response when is activated The green LED next to the knob lights up to indicate Presence B is active Input Jack 6 3 mm unbalanced input jack Plug your guit...

Страница 8: ...h II and Lead Middle This is the preamp voicing section s passive midrange frequency EQ for Crunch II and Lead Treble This is the preamp voicing section s passive hi frequency EQ for Clean Crunch II a...

Страница 9: ...act duplicate of an existing preset The system will select a WRITE operation whenever you edit a MIDI preset that is when you have modified a programmable feature You ll know that this is the case bec...

Страница 10: ...he master level FX Loop I II Switch This button switches to and from between FX Loop I and FX Loop II The red LED above the button lights up to indicate is on You can also select loops via MIDI progra...

Страница 11: ...et the Stand By switch to the 0 position Power Switch Mains power on off PLEASE NOTE ensure that the Stand By is set to Stand By 0 position before you switch the amp on Let the tubes heat up for about...

Страница 12: ...evice always make sure that the ENGL MIDI Footcontroller Power Supply switch is set to the right to avoid damaging the device ENGL Midi Footcontroller Power Supply This selector activates a MIDI In po...

Страница 13: ...ting the small switch labeled 6 to ON enables the MIDI controller access capability for certain Amp functions Setting the small switch labeled 6 to OFF disables the MIDI controller access capability f...

Страница 14: ...t is disabled when the Z9 is connected CAUTION Connect only the ENGL Z9 to this 6 3 mm stereo jack Connecting any other switching device may damage it and or the amp s circuitry Footswitch Clean Crunc...

Страница 15: ...wet balance 1 99 depending on knob position When the knob arrives at the Effect position only the wet signal that is the processed signal generated by the connected effect device is patched to the po...

Страница 16: ...oss of a power tube results in an unbalanced signal Be sure to have a specialist look over the power amp as soon as possible the fuse probably blew because of a defective power tube Once a fuse has bl...

Страница 17: ...ne of the 4 Ohm jacks in combination with a 16 Ohm cabinet connected to one of the 8 Ohm jacks Summary 8 Z 16 Z connected to 4 ohm 8 ohm output NOTE Never operate the power amp without a sufficient lo...

Страница 18: ...T L T slow blow E610II Power Tube Fuses 2 x 0 16 AM M medium blow E630II 2 x 0 315AM M medium blow E610II Important Replace these with fuses oft he same type and rating only Tubes V1 ENGL ECC83 First...

Страница 19: ...cooling which increases component life Never operate the amp without an adequate load a speaker cabinet or suitable terminating resistor High ambient temperatures place an additional strain on diverse...

Страница 20: ...clock position This type of configuration can cause considerable feedback that could well damage your hearing and de stroy speakers If you set the Volume or Master knobs to higher volume levels always...

Страница 21: ...switches continuously connect to GND when you wish to activate the given function If you re unsure about the answers to these questions consult an authorized service centre or a professional specialis...

Страница 22: ...hts up F1 4 Function 1 1 Channel 1 LED 1 flashes F1 5 Function 1 Gain Lo Hi 1 Channel 2 LED 2 flashes F1 6 Function 1 Bright 1 Channel 3 LED 3 flashes F1 7 Function 1 Noise Gate 1 Channel 4 LED 4 flas...

Страница 23: ...y Stereo 6 3 mm plug Stereo 6 3 mm plug Very important use a stereo plug only Custom Z 9 Footswitch only Serial Amp Control Port Dual Footswitch ring Data tip 5 Volts ring Sub I II tip CHI CHII Error...

Страница 24: ...www engl amps com...

Отзывы: