The overload indicator light
①
comes on when an overload of a connected
electrical device is detected, the inverter control unit overheats, or the AC
output voltage rises. Then, the AC protector will trip, stopping power generation
in order to protect the generator and any connected electric devices. The AC
pilot light (Green) will go off and the overload indicator light (Red) will stay
on, but the engine will not stop running.
When the overload indicator light comes on and power generation stops,
proceed as follows:
1. Turn off any connected electric devices and stop the engine.
2. Reduce the total wattage of connected electric devices within the rated
output.
3. Check for blockages in the cooling air inlet and around the control unit.
If any blockages are found, remove.
4. After checking, restart the engine.
4.3 Overload indicator light (Red)
Tip:
The overload indicator light may come on for a few seconds at first when
using electric devices that require a large starting current, such as a compressor
or a submergible pump. However, this is not a malfunction.
4.4 AC pilot light (Green)
The AC pilot light
①
comes on when the engine starts and produces power.