Страница 1: ...2 5kW R2500IS...

Страница 2: ......

Страница 3: ...m the actual parts due to revision and other changes Our company reserves the right to make changes at any time without notice and without incurring any obligation No part of this publication may be r...

Страница 4: ...SAFETY WARNINGS Personal safety and property safety of you and others are very important Please read these messages which is preceded by a symbol or carefully 2...

Страница 5: ...13 4 4 AC pilot light Green 13 4 5 Engine smart control ESC 14 4 6 Fuel tank cap 15 4 7 Fuel tank cap air vent knob 15 4 8 Ground Earth terminal 15 5 PREPARATION 16 5 1 fuel 16 5 2 Engine oil 17 5 3...

Страница 6: ...placement 29 7 4 Air filter 30 7 5 Muffler screen and spark Arrester 31 7 6 Fuel tank filter 32 7 7 Fuel filter 32 8 STORAGE 33 8 1 Drain the fuel 33 8 2 Engine 34 9 TROUBLESHOOTING 35 9 1 Engine won...

Страница 7: ...erating your generator It will help you avoid accidents if you get familiar with your generator s safe operation procedures 1 SAFETY INFORMATION Never use it indoors Never use it in a wet conditions N...

Страница 8: ...Keep it at least 1m away from inflammables Never smoke when fueling Don t spill when fueling Stop the engine before fueling 6...

Страница 9: ...ofessional electrician or by another person with proficient electrical skill When the loads are connected to the generator please carefully check whether electrical connections are safe and reliable A...

Страница 10: ...with a good quality insulated conductor Ground terminal 8 Make sure no chips mud and water come inside of the unit from openings of control panel louver and inverter Otherwise the unit may be damaged...

Страница 11: ...Please read the following labels carefully before operation this machine TIP Maintain or replace safety and instruction labels as necessary 2 LOCATION OF IMPORTANT LABELS 9 5 4 5 4...

Страница 12: ...3 DESCRIPTION Carrying handle Fuel tank cap air vent knob Fuel tank cap Control panel Recoil starter Oil filler cap Handle Inverter wheel Louver Muffler Spark plug maintenance cover 10...

Страница 13: ...t Parallel function V F T Meter Voltage Frequency Time Overload indicator light AC pilot light ESC Engine Smart Control 3 in 1 switch knob including start stop switch fuel valve and choke AC receptacl...

Страница 14: ...ched on Fuel is switched on Choke is switched off The engine can be started TIP The choke is not required to start a warm engine 4 2 Oil warning light Red When the oil level falls below the lower leve...

Страница 15: ...generation stops proceed as follows 1 Turn off any connected electric devices and stop the engine 2 Reduce the total wattage of connected electric devices within the rated output 3 Check for blockage...

Страница 16: ...d load The results are better fuel consumption and less noise OFF When the ESC switch is turned to OFF the engine runs at the rated r min 4400r min regard less of whether is a load connected or not Ti...

Страница 17: ...el flow The air vent knob must be turned to ON This will allow fuel to flow to the carburetor and the engine to run when the engine is not in use turn the air vent knob to OFF to stop fuel flow 4 8 Gr...

Страница 18: ...sonous Check SAFETY INFORMA 5 1 Fuel may deteriorate painted surfaces or plastic parts Use only unleaded petrol The use of leaded petrol will cause severe damage to internal engine parts Remove the fu...

Страница 19: ...ace 2 Remove the screws and then remove the cover 3 Remove the oil filler cap 5 2 Engine oil 4 Fill the specified amount of the recommended engine oil and then install and tighten the oil filler cap 5...

Страница 20: ...erator is used Locate set in convenient place avoiding long extension leads and possible damage to leads by pedestrian or vehicular traffic Maintain normal safety precautions with appliances and acces...

Страница 21: ...s could result in overfilling and damage to the engine TIP The generator can be used with the rated output load at standard atmospheric conditions Standard atmospheric conditions Ambient temperature 2...

Страница 22: ...position ON The choke is not required to start a 4 Pull slowly on the recoil starter until it is engaged then pull it briskly TIP Grasp the carrying handle firmly to prevent the generator from falling...

Страница 23: ...or 3 minutes to warm up the engine The ESC unit operates normally after the above time period while the ESC is ON TIP Turn off any electric devices 6 2 Stopping the engine 1 Turn the ESC to OFF 2 Disc...

Страница 24: ...le rated current TIP Make sure to ground Earth the generator When the electric device is earthed always the generator must be earthed 1 Start the engine 2 Turn the ESC to ON 3 Plug in to AC receptacle...

Страница 25: ...material is flame resistant black plastic ABS The USB ports are equipped with dust proof cover FEATURES SPECIFICATION 1 Working power supply DC 15V 35V 2 Max no load output voltage limit is DC5 5 25 3...

Страница 26: ...fficiency 0 85 AC TIP should not exceed the rated output EX Application wattage indicates when each device is used by itself The simultaneous usage of AC and DC power is possible but total wattage Gen...

Страница 27: ...btained from the manufacturer a medical professional or hospital Some electrical appliances or general purpose electric motors have High starting currents and cannot therefore be used even if they lie...

Страница 28: ...d is proficient with mechanical maintenance Engine oil Reduction gear oil if equipped Air filter element Deposit Cup if equipped Spark Plug Spark arrester Idling if equipped Valve clearan ce Fuel tank...

Страница 29: ...your engine do it as soon as possible If the petrol engine frequently works under high temperature or heavy load change the oil every 25 hours Stop the engine before servicing Put the engine on a lev...

Страница 30: ...ctrode of spark plug should be a medium to light tan color 4 Check the spark plug type and gap a Standard Spark Plug A5RTC Spark Plug Gap 0 6 0 8mm 0 024 0 031in Spark Plug Torque 12 5 N m 1 25kgf m 9...

Страница 31: ...should be handled with care to avoid burns 1 Place the generator on a level surface and warm up the engine for several minutes Then stop the engine and turn the 3 in 1 switch knob and fuel tank cap a...

Страница 32: ...he screws 7 4 Air filter 1 Remove the screws and then remove the cover 2 Remove the screw and then remove the air filter case cover 3 Remove the foam element 4 Wash the foam element in solvent and dry...

Страница 33: ...e engine and muffler while they are still hot with any part of your body or clothing during inspection or repair When cleaning use the wire brush lightly to avoid damaging or scratching the muffler sc...

Страница 34: ...Be sure the fuel tank cap is tightened securely 7 7 Fuel filter 1 Remove the screws and then remove the cover and drain the fuel 2 Hold and move up the clamp then take off the hose from the tank 3 Ta...

Страница 35: ...to OFF 2 Remove the fuel tank cap remove the filter Extract the fuel from the fuel tank into an approved petrol container Then install the fuel tank cap Fuel is highly flammable and poisonous Check S...

Страница 36: ...art the engine See Page 20 and leave it run until it stops The engine stops in approx 20 minutes Time by running out of fuel 8 2 Engine Perform the following steps to protect the cylinder piston ring...

Страница 37: ...oil system Insufficient Oil level is low Add engine oil Oil level cap Oil level lower limit 3 Electrical systems Put the 3 in 1 switch to CHOKE and pull the recoil starter Poor spark Spark plug dirty...

Страница 38: ...utput USB A Generator Engine Generator set R2500iS Inverter 50 230 2 3 1 ISO8528 G2 5 0 3 Continue Running Time at rated power h Engine Oil Capacity L Spark Model No Starting mode Length Width Height...

Страница 39: ...to Ignition Coil Stepper Motor Ignition Pulse Rectifier Bridge Control Panel Idel Reset switch Speed Switch Oil Parallel Receptacle Indicator Failure Indicator Running Indicator Auto Recovery 5A Contr...

Страница 40: ...ermine there is no defect or that the defect resulted from causes not within the scope of warranty then you must bear the cost of returning the product or part To ensure prompt and complete warranty c...

Страница 41: ...any other reasonably foreseeable loss or damage You are also en tled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major fai...