background image

Figure 3:
Programming the SK-983A Keypad

Figure 1:
Visible and Audible Indicators

The built-in buzzer and the amber LED generate tones and
signals to indicate programming status as shown in Figure 1.

PROGRAMMING THE RELA

PROGRAMMING THE RELA

PROGRAMMING THE RELA

PROGRAMMING THE RELA

PROGRAMMING THE RELAY

YY

YY

The 5A relay can be programmed for N.O. operation via the
on-board wire jumper.  See figure 2.

PCB

WIRE

WIRE

WIRE

WIRE

WIRE

MALE

MALE

MALE

MALE

MALE
POST

POST

POST

POST

POST

FEMALE

FEMALE

FEMALE

FEMALE

FEMALE
SOCKET

SOCKET

SOCKET

SOCKET

SOCKET

N

N

N

N

N.O

.O

.O

.O

.O.....

N

N

N

N

N.C.

.C.

.C.

.C.

.C.

SOLDER

SOLDER

SOLDER

SOLDER

SOLDER

Figure 2:
Programming
for N.O. or
N.C. output

PROGRAMMING THE KEYP

PROGRAMMING THE KEYP

PROGRAMMING THE KEYP

PROGRAMMING THE KEYP

PROGRAMMING THE KEYPAD

AD

AD

AD

AD

To program the SK-983A, you will first need to decide the following information:
-

The Master Code and/or the User Code.

-

Relay configuration — momentary or shunt, and relay momentary output time (1 to 999 seconds) in momentary mode.

-

Whether or not Quick Code is to be used.

-

Result of improper code entry after 10 successive tries (30-second code lockout,  Duress output, or neither).

Now you can program the keypad as shown in Figure 3.

FFFFFA

A

A

A

ACT

CT

CT

CT

CTOR

OR

OR

OR

ORY

YY

YY-----SET D

SET D

SET D

SET D

SET DA

A

A

A

ATTTTTA -- IMPORT

A -- IMPORT

A -- IMPORT

A -- IMPORT

A -- IMPORTANT NO

ANT NO

ANT NO

ANT NO

ANT NOTE

TE

TE

TE

TE

For convenience in first-time programming, the SK-983A comes preprogrammed with the Master Code 0000.  Additional
codes and or data should be programmed at the owner’s discretion.  However, to ensure security, the owner should program
a personal Master Code to replace the factory-set Master Code.

PROGRAMMING THE KEYP

PROGRAMMING THE KEYP

PROGRAMMING THE KEYP

PROGRAMMING THE KEYP

PROGRAMMING THE KEYPAD (EXAMPLE)

AD (EXAMPLE)

AD (EXAMPLE)

AD (EXAMPLE)

AD (EXAMPLE)

In this example, the following data will be stored in the keypad:
-

Change the factory Master Code 0000 to a personal Master Code 3289.

-

Set the User Code to 8321

-

Set the relay output to momentary mode, 5 seconds.

-

Set the keypad to lock 30 seconds after 10 consecutive incorrect code inputs.

Programming — Enter the data as follows:

0 0 0 0 *

Enter the programming mode using the factory-set Master Code.

0 3 2 8 9 #

3289 has been stored as the new personal Master Code.

1 8 3 2 1 #

8321 has been stored as the new User Code.

4 0 5 #

The relay output has been set to momentary mode with 5-second output.

7 0 #

The keypad has been set to lockout code entry for 30 seconds following 10 consecutive incorrect code
entries.

*

Exit programming mode, with all desired data stored.

Note:  If you make a mistake, press the “#” to cancel, or wait 10 seconds, then re-enter.

USING THE KEYP

USING THE KEYP

USING THE KEYP

USING THE KEYP

USING THE KEYPAD (EXAMPLES)

AD (EXAMPLES)

AD (EXAMPLES)

AD (EXAMPLES)

AD (EXAMPLES)

The following examples use the sample data programmed above.

Example 1 — Activate the 5A relay with the User Code.

To activate the relay output (for instance, to energize the electric door striker), enter the User Code followed by the “#” key.

8 3 2 1 #

The relay output will be active for 5 seconds.

Example 2 — Activate the 5A relay with the Master Code.

Under normal circumstances, the User Code is used to activate the relay.  However, if several keypads are programmed with
the same personal Master Code but different User Codes, the relay can be activated by typing in the Master Code followed by “#1.”

3 2 8 9 # 1

Relay output will be activated for 5 seconds.

Example 3 — Duress Code.

If a user is being forced by a thief to use the keypad to open a door, he/she can use the Duress Code.  This allows a user under
duress to activate the 5A relay and trigger an alarm at the same time.  The keypad determines it automatically by adding 2
to the first digit of the User Code.  (Example:  If the User Code is “1234,” then the Duress Code is “3234.”  If the User Code is
“8321,” then the Duress Code is “0321.”)  To activate the Duress Output, enter the Duress Code followed by the “#” key.

0 3 2 1 #

The relay output will be active for 5 seconds, and a Duress signal is sent to an alarm control device.

Example 4 — Using the Quick Code

The Quick Code, if programmed, allows the keypad to latch the relay ON by keying the first 2 digits of the User Code.  To turn
the relay OFF, key in the entire User or Master Code.  This is useful when, for instance, the relay needs to be ON during the
day to allow unrestricted access to the protected premises, but OFF during the evening to restrict access.  In this example, the
supervisor uses the Quick Code to latch the relay ON in the morning, and the User Code to shut it off in the evening.

Amber

Buzzer

STATUS

LED output tones

ON

none

In programming

mode

1 flash

1 beep

Successful key

entry

2 flashes

2 beeps

Successful code

entry

5 flashes

5 beeps

Unsuccessful

code entry

Continuous Continuous DAP jumper not

flash

beeps

replaced

1 flash every none

Standby mode

2 seconds

Access Keys

Entry

Validation

Comments

First-time use -- Set the Personal Master Code

--

Master Code (factory

*

Enter the programming mode by keying in

pre-set at 0000)

the Master Code

Programming -- Changing Master and User Codes

0

From 1 to 8 digits

#

Sets the 1 to 8 digit personal Master Code

1

From 1 to 8 digits

#

Sets the 1 to 8 digit User Code

Programming -- Configuration of relay output

40

Relay activate time

Relay has momentary output of 1 to 999 (from

to 999 seconds)

#

1 seconds each time the User Code is inputted

41

--

#

Relay latches ON or OFF each time the User

Code is inputted

42

--

#

Relay latches ON each time the Quick Code is

inputted

Programming -- Personal safety

70

--

#

After 10 successive incorrect code attempts,

keypad locks out code for 30 seconds

71

--

#

After 10 successive incorrect code attempts,

keypad outputs Duress signal

72

--

#

Neither of the above

Exit programming mode

--

--

*

Exits programming mode, returns to normal

operation

_______________________________________________________

_______________________________________________________

_____________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

Отзывы: