24
ENFORCER Vandal Resistant Access Control Keypads
SECO-LARM U.S.A., Inc.
Programming the Wrong-Code System Lock-Up:
The keypad can be programmed to lock up in order to secure the premises against unauthorized
entry if multiple wrong codes are entered or multiple wrong user cards* are tapped.
When programming the wrong-code system lock-up, use this general formula:
60 aa #
60
– Program Wrong-Code System Lock-Up
AA
– Lock Options
Lock Options:
Choose from several different options for the wrong-code system lock-up security level:
•
1
– After 10 successive false attempts using incorrect user codes or user cards*, the keypad
will lock for 60 seconds (default).
•
2
– After 10 successive false attempts using incorrect user codes or user cards*, the duress
output will activate. The duress output can be deactivated using any user code or user card, or
via the super user code.
•
5
to
10
– After 5 to 10 successive false attempts using incorrect user codes or user cards*,
the keypad will lock for 15 minutes or until the super user code is used as follows:
SUPER USER CODE
# 9
•
00
– No system lock-up will happen.
NOTE
: The keypad’s red LED will remain lit to show that the keypad is locked. The duress code
will still function in this mode.
Programming the User Code Entry Mode:
The keypad can be programmed for auto or manual user code entry modes:
•
Auto entry mode – Pressing the
#
key is not required after typing in a user code. In auto entry
mode, all user codes must have the same number of digits as the master code.
•
Manual entry mode – The
#
key must be pressed after the user code to indicate the code has
been entered completely. In this case, the user codes can have a different number of digits, from
4 to 8 digits.
To Program:
•
For auto entry mode:
70 1 #
•
For manual entry mode (default):
70 2 #
*SK-1123-SPQ only