ENFORCER Vandal Resistant Access Control Keypads

SECO-LARM U.S.A., Inc.

Getting Ready to Program:

Sample Applications (continued):

Codes and/or Cards*:

The keypad can be set to be activated by users in one of three ways:
1. 

Keypad code only – There are five types of keypad codes:

 

Master code – Used only for entering programming mode; there can be only one master 

code per keypad.

 

Super user code – Can be used to activate outputs #1 and #2, or to disable (inhibit) or 

enable the operation of output #1. 

 

User codes – Unique codes for each user to activate outputs #1 or #2. 

 

Visitor codes – Temporary user codes that can be assigned to visitors or temporary 

workers to activate output #1; the visitor codes can be programmed for one-time use or 

to expire after a set number of hours has passed.

 

Duress codes – Assigned to specific users as a way to send a silent alert if forced to use 

the keypad under duress.

2. 

Proximity card only* – Standard 125kHz (EM125) proximity cards can be used to activate 

outputs #1 or #2.

3.  Card* + code – For enhanced security, the user can be required to also enter a code after 

tapping a proximity card. The code may be unique to each card or to a group of users, or a 

common code can be used with all cards.

Security Levels:

There are four possible security levels for the keypad:
1.  Card only* – The most basic, convenient level of security. Hold a previously-programmed 

proximity card over the keypad to activate outputs #1 or #2 (see “Programming User Codes 

and Proximity Cards” on pages 16~17).

Door-Hold-Open Mode:

1. 

For N.C. locking devices, connect outputs in 

series with working device.

2.  For N.O. locking devices, connect outputs in 

parallel with locking device.

*SK-1123-SPQ only

Содержание SECO-LARM SK-2612-SFSQ

Страница 1: ...Vandal Resistant Outdoor Access Control Keypads Manual SK 1123 SPQ shown Model Number 2 Outputs Backlit Keys Proximity Reader SK 1123 SDQ SK 1123 SPQ...

Страница 2: ...S A Inc Quick Installation Guide Mounting Diagram Quick Wiring Diagram This page is for installers looking to do a basic installation and programming of the keypad For more in depth installation and p...

Страница 3: ...Programming Instructions Follow the instructions below if the following covers your needs A new master code A single 4 digit user code for all users and no proximity cards One output to unlock a door...

Страница 4: ...15 16 Programming User Codes and Proximity Cards 16 17 Programming Visitor Codes for Output 1 18 Programming Duress Codes 19 20 Programming the Output Mode and Output Timing 21 Programming the Real Ti...

Страница 5: ...e user codes 000 999 and or proximity cards programmable for output 1 and 100 001 100 for output 2 Up to 50 01 50 possible temporary visitor codes which can be programmed for one time or limited time...

Страница 6: ...ntinuous beeping Continuous flashing Output relay activation 2 1 Sec long beep In standby mode 3 1 Flash sec System restore mode 2 Beeps Fast flashing for 2 5 min Card code already stored 1 Long beep...

Страница 7: ...to the back box with the included installation screws 1 Always disconnect power before servicing the keypad Do not apply power until all connection wiring is completed 2 The keypad must be properly g...

Страница 8: ...ode Ground Common ground output Door Sensor Connect to an optional N C sensor such as a magnetic contact to monitor if a door is open or closed Connect to ground if not used Output 1 Inhibit Output 1...

Страница 9: ...is application the keypad is connected to a single door lock and an egress pushbutton Inter Lock System Using Two Keypads In this application two keypads are each connected to separate door locks and...

Страница 10: ...fter a set number of hours has passed Duress codes Assigned to specific users as a way to send a silent alert if forced to use the keypad under duress 2 Proximity card only Standard 125kHz EM125 proxi...

Страница 11: ...or about 1 minute During this power up time if needed use Direct Access to Programming DAP to reset the master code see Direct Access to Programming DAP on page 29 1 Turn off the beeping before the 1...

Страница 12: ...Visitor codes for output 1 No default must be programmed 17 18 41 Duress codes for output 1 No default must be programmed 19 20 42 Duress codes for output 2 No default must be programmed 19 20 51 Out...

Страница 13: ...t to their default values and are ready to be re programmed At this point the keypad is still in programming mode The master code is used to enter programming mode The master code does not serve as a...

Страница 14: ...Programming Mode on page 11 2 Enter the new super user code 02 xxxx NOTE XXXX represents the new super user code which can be 4 to 8 digits long There can be only one super user code for the keypad Pr...

Страница 15: ...used 5 Disable or enable output 1 toggle regardless of programming 2580 9 NOTE For more information on programming timed or toggle mode see Programming the Output Mode and Output Timing on page 21 Th...

Страница 16: ...user code to activate outputs 1 or 2 3 Card Unique user code The most secure level This code is programmed separately for each card and can be unique to the card or the same code can be used for a gr...

Страница 17: ...isitor duress and user codes cannot be the same Examples 1 Program only a proximity card for user ID 017 for output 1 10 1 017 READ CARD 2 Program a user code for user ID 010 for output 1 10 2 010 227...

Страница 18: ...visitor IDs for visitor codes for output 1 0999 Delete all currently programmed visitor codes Valid Duration 00 Set a one time code This code can only be used once by a visitor after which it is auto...

Страница 19: ...gramming User Codes and Proximity Cards on pages 16 17 The duress code should be easy to remember For instance it can be the same as a user s normal user code but with a single digit changed as by sub...

Страница 20: ...deactivate the duress output Only a normal user code card super user code or a master code can deactivate the duress output NOTE A duress code can also be used in conjunction with a user card to acti...

Страница 21: ...put B Output Mode and Time Outputs 51 Output 1 52 Output 2 Output Mode and Time 0 Start stop toggle mode In this case the output starts when a user code and or user card is entered and stops when a us...

Страница 22: ...imes every 5 seconds To deactivate this alert either reset the real time clock or clear the output 1 auto disable time If the output 1 auto disable time is not programmed losing power will not cause t...

Страница 23: ...am Output 1 Auto Disable Time HHMM Start Time HHMM End Time Start Time Start time for output 1 auto disable time HH represents hours and MM represents minutes in the military 24 hour time format from...

Страница 24: ...deactivated using any user code or user card or via the super user code 5 to 10 After 5 to 10 successive false attempts using incorrect user codes or user cards the keypad will lock for 15 minutes or...

Страница 25: ...eeps are disabled However the warning and power up delay beeps remain active This provides for a quieter work environment To Program To enable keypad audible mode default 71 1 To enable keypad silent...

Страница 26: ...ed to an optional magnetic contact or other door protection switch or device the keypad can be programmed to beep when a door has been forced open The keypad beep can be set to activate for 1 to 999 s...

Страница 27: ...propped open This prompts authorized users to close a door that was not closed properly or to investigate a door that may have been deliberately propped open Door propped open warning OFF default 81...

Страница 28: ...tarily The door opens instantly default or after the programmed delay time with no audible warning 2 Momentary contact with warning beep Press the egress button momentarily The keypad will beep for th...

Страница 29: ...Programming DAP is used to enter programming mode if the master code is forgotten DAP will not change the programming of the keypad in any way To Use DAP 1 Disconnect the keypad s power 2 Wait one mi...

Страница 30: ...30 ENFORCER Vandal Resistant Access Control Keypads SECO LARM U S A Inc Notes...

Страница 31: ...code READ CARD 2 Short beeps and a rapidly flashing amber LED indicates the card is accepted and the keypad is waiting for the Common user code 3526 1 Long beep indicates that the door can be opened S...

Страница 32: ...ibuted to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such eq...

Отзывы: