Installation: 

1.

 

Drill holes as shown above and mount the enclosure base. For weatherproof installation, install to a 
flat surface so the rubber sealing pad has a good seal. Otherwise apply silicone sealant (not 
included) around the back of the base before installing. Thread the wires through the wiring hole. 

2.

 

Connect the wires from to the Request-to-Exit Sensor according the 

Wiring Diagram

 above. 

3.

 

Slide the sensor plate and plastic mounting rails into the enclosure base and use the two screws to 
attach the manual override assembly taking care not to crimp the wires (see Overview, pg. 2).  

4.

 

Tamp the screw plugs into the holes. Remove clear protective film from the sensor before use. 

WARNING:

 Do not connect any device that will exceed 1A@24VDC. 

Changing the LED Color Jumper Placement: 

 

Adjusting the sensor range and trigger time: 

1.

 

The sensor range can be adjusted from 1

9

/

16

"~6" (4~15 cm). 

2.

 

The trigger time can be adjusted from 0.5~30 seconds or toggle.* 

NOTE: 

Do not force the adjustment trimpots to turn. Only minimal 

force is needed. 

 

 

 

Standby: Green 
Trigger: Red

 

Standby: Red 
Trigger: Green 

(default) 

COM 

Use disassembled enclosure 
base as a template to mark the 
locations of the 4 mounting holes 
and wiring hole for drilling. 

Red Wire: +12~24VDC 

 

Brown Wire: Ground (-) 

 

Blue Wire: COM 

 

Purple Wire: N.O. 

 

Green Wire: N.C. 
 

NC 

NO 

Manual override 

assembly

 

Relay (N.O.) 
Relay (COM)

 

Relay (N.C.) 
– GND 
+ 12~24VDC 

5-Pin Terminal

 

Sensor 

plate

 

Green 

wire

 

Blue 

wire

 

Trigger time 
adjustment

 

Sensor range 
adjustment

 

Sensor Back

 

Screw plugs

 

Housing assembly 
screws

 

Screw Plugs:

 

Trigger time: 0.5~30 seconds, toggle* 

Default: 0.5 seconds   

*Set trigger time to maximum for toggle 

 

0.5s 

30s 

Sensor range: 1

9

/

16

"~6" (4~15 cm) 

Default: 6" (15cm) 

15cm 

4cm 

Содержание SECO-LARM SD-9773-KNEVQ

Страница 1: ... sensor range up to 6 15cm 1A relay adjustable trigger duration 0 5 30 seconds or toggle LED illuminated sensor area for easy identification Selectable LED colors turns from red to green or green to red when sensor is activated Aluminum alloy and ABS plastic housing IP54 Weather resistant for outdoor use ...

Страница 2: ...C 26mA 24VDC Triggered green 26mA 12VDC 32mA 24VDC Standby green 16mA 12VDC 20mA 24VDC Triggered red 31mA 12VDC 39mA 24VDC Relay type SPDT dry contact 1A 24VDC Response time 10ms LEDs Standby Red Triggered Green Output time 0 5 30 s toggle Range 19 16 6 4 15 cm IP rating IP54 Housing material Aluminum alloy with ABS plastic Operating temperature 4 131 F 20 55 C Dimensions 31 8 x 41 2 x11 8 80x115x...

Страница 3: ...e WARNING Do not connect any device that will exceed 1A 24VDC Changing the LED Color Jumper Placement Adjusting the sensor range and trigger time 1 The sensor range can be adjusted from 19 16 6 4 15 cm 2 The trigger time can be adjusted from 0 5 30 seconds or toggle NOTE Do not force the adjustment trimpots to turn Only minimal force is needed Standby Green Trigger Red Standby Red Trigger Green de...

Страница 4: ...M This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the pu...

Отзывы: