ENFORCER ENFORCER SK-910RC4Q Скачать руководство пользователя страница 7

ENFORCER SK-910RC4Q Central Receiver 

SECO-LARM U.S.A., Inc.                                                                                     

 

 

 

 

Setting the Power LED: 

The power LED can be set to Bright, Dim, or OFF using the power LED jumper. 
1.

 

Locate the jumper on the PCB as shown below. 

2.

 

Place the jumper on the middle and right pins for Dim, and on the middle and left pins for Bright. 

3.

 

Remove the jumper or place on the left or right pin only to set the power LED to OFF. 

Sample Applications: 

1.

 

A photobeam sensor installed on a driveway (E-960-D90Q or similar) is connected to an  
RF wired transmitter (SK-919TDWS-BU or similar).  When the photobeam sensor is 
triggered, the transmitter sends a signal to the SK-910RC4Q Central Receiver. 

2.

 

Inside, an alarm, lamp, or other signaling device is connected to the channel’s relay output.  
When the intruder triggers the photobeam sensor, an alarm is triggered or the light turns on. 

3.

 

Alternatively, a DVR (DR-1 series or similar) can be connected to an RF wired transmitter.  
When an event (such as motion detection) occurs on the DVR, the transmitter sends a signal 
to the SK-910RC4Q Central Receiver, alerting the user and activating the channel relay. 

4.

 

In addition to connecting a signaling device to the channel relay output, an auxiliary device 
such as an LED strobe light (SL-1301 series or similar), can be powered by the SK-910RC4Q 
Central Receiver when a channel is activated. 

Power LED jumper settings  

Bright 

Dim 

Jumper 

PCB 

Off 

Outside driveway 

Indoor location 

Recording station 

E-960-D90Q 

SK-919TDWS-BU 

Lamp 

SL-1301-BAQ 

SK-919TDWS-BU 

DR-116Q 

SK-910RC4Q 

Содержание ENFORCER SK-910RC4Q

Страница 1: ...te Model numbers that end with Q or that have a round green Q sticker signify RoHS compliant products 4 Channels 4 Channel relay outputs 1 Auxiliary relay output 12VDC 4 Relay output modes 4 Programma...

Страница 2: ...s garage door openers lights motorized gates lifts and other devices RF frequency 315MHz of RF channels 4 Alert sound 100 3dB 10cm adjustable Number of alert tones 4 programmable Connectors 14 Pin ter...

Страница 3: ...attempting to release point 4 gently slide the bottom cover down and left to bring the programming buttons out of their holes in the housing Installation Notes Overview 4 Disconnect the speaker plug...

Страница 4: ...eceiver channel can learn the codes of up to 15 different transmitters Transmitters are learned on a first in first out basis For example if 15 transmitter codes have been learned when a new transmitt...

Страница 5: ...Output of Flashes Output Mode 3 Latch Output 4 Validity Output Example 1 If the present mode is Timed Output and the desired mode is Latch Output press the channel s programming button 2 times Example...

Страница 6: ...lay terminals are the left most terminals on the terminal block as shown in the diagram below 2 Select which channels will trigger the auxiliary relay using the Auxiliary Relay DIP switch SW8 located...

Страница 7: ...side an alarm lamp or other signaling device is connected to the channel s relay output When the intruder triggers the photobeam sensor an alarm is triggered or the light turns on 3 Alternatively a DV...

Страница 8: ...pment and improvement For this reason SECO LARM reserves the right to change specifications without notice SECO LARM is also not responsible for misprints or typographical errors Copyright 2010 SECO L...

Отзывы: