Specifications:
Troubleshooting:
MiE932-D33TBQc.PMD
PITSW3
®
Yellow LED or RX Red LED
does not turn off.
1) Dirty sensor and/or reflector.
2) Reflector and/or sensor is misaligned.
1) Clean the sensor and reflector with a
damp (not wet) cloth.
2) Adjust the reflector and/or sensor for
proper alignment.
Red LED lights when object is
detected, but no output.
No continuity between sensor and alarm
device.
Check cable from sensor to alarm device.
Test sensor.
Sensor does not detect the object.
Object may have a reflective surface
which confuses sensor.
Change the angle of the sensor.
Trouble
Remedy(s)
Possible Origin(s)
Notice:
The information and specifications printed in this manual are current at the time of publication. However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change
specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2007 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part,
without the written permission of SECO-LARM.
SECO-LARM® U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
Website: www.seco-larm.com
E-mail: [email protected]
Warranty:
This SECO-LARM product is warranted against defects in material and workmanship while
used in normal service for a period of one (1) year from the date of sale to the original consumer customer.
SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned,
transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or
alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment
is not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair
only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or
consequential personal or property damages of any kind to the purchaser or anyone else.
Red LED does not turn on.
No power.
Check power.
E-932-S16RRQ
Type
Reflective beam
Dual through beam
Sensing Range
16 ft (5m)
33 ft (10m)
Supply Voltage
12~18VDC
12~18VDC
Current Drain
5 0 m A max.
5 0 m A max.
Response Time
10msec.
10msec.
Light Source
IR LED
IR LED
LEDs
Red (on): Power
TX Red (on): Power
Yellow (off): Aligned
RX Red (off): Aligned
Yellow (on): Out of alignment
RX Red (on): Out of alignment
Output
N.C., N.O., Common
N.C., N.O., Common
Switching Capacity
1A@120V (AC/DC)
1A@120V (AC/DC)
Ambient Temp
14
°
~122
°
F (-10
°
~50
°
C)
14
°
~122
°
F (-10
°
~50
°
C)
Alignment Angle
Vert. ±15
°
, Horiz. ±15
°
Vert. ±15
°
, Horiz. ±15
°
E-932-D33TBQ