Specifications:

Troubleshooting:

MiE932-D33TBQc.PMD

PITSW3

®

Yellow LED or RX Red LED
does not turn off.

1) Dirty sensor and/or reflector.
2) Reflector and/or sensor is misaligned.

1) Clean the sensor and reflector with a
damp (not wet) cloth.
2) Adjust the reflector and/or sensor for
proper alignment.

Red LED lights when object is
detected, but no output.

No continuity between sensor and alarm
device.

Check cable from sensor to alarm device.
Test sensor.

Sensor does not detect the object.

Object may have a reflective surface
which confuses sensor.

Change the angle of the sensor.

Trouble

Remedy(s)

Possible Origin(s)

Notice:

 

The information and specifications printed in this manual are current at the time of publication.  However, the

SECO-LARM policy is one of continual development and improvement.  For this reason, SECO-LARM reserves the right to change

specifications without notice.  SECO-LARM is also not responsible for misprints or typographical errors.

Copyright © 2007 SECO-LARM U.S.A., Inc.  All rights reserved.  This material may not be reproduced or copied, in whole or in part,
without the written permission of SECO-LARM.

SECO-LARM® U.S.A., Inc.

16842 Millikan Avenue, Irvine, CA  92606

Tel: 800-662-0800 / 949-261-2999   Fax: 949-261-7326

Website: www.seco-larm.com
E-mail: [email protected]

Warranty:

 

This SECO-LARM product is warranted against defects in material and workmanship while

used in normal service for a period of one (1) year from the date of sale to the original consumer customer.
SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned,
transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or
alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment
is not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair
only, at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or
consequential personal or property damages of any kind to the purchaser or anyone else.

Red LED does not turn on.

No power.

Check power.

E-932-S16RRQ

Type

Reflective beam

Dual through beam

Sensing Range

16  ft (5m)

33 ft (10m)

Supply Voltage

12~18VDC

12~18VDC

Current Drain

5 0 m A  max.

5 0 m A  max.

Response Time

10msec.

10msec.

Light Source

IR LED

IR LED

LEDs

Red (on):  Power

TX Red (on): Power

Yellow (off): Aligned

RX Red (off): Aligned

Yellow (on): Out of alignment

RX Red (on): Out of alignment

Output

N.C., N.O., Common

N.C., N.O., Common

Switching Capacity

1A@120V (AC/DC)

1A@120V (AC/DC)

Ambient Temp

14

°

~122

°

F (-10

°

~50

°

C)

14

°

~122

°

F (-10

°

~50

°

C)

Alignment Angle

Vert. ±15

°

, Horiz. ±15

°

Vert. ±15

°

, Horiz. ±15

°

E-932-D33TBQ

Содержание E-932-D33TBQ

Страница 1: ...ty of explosive gasses being present INSTALLATION MANUAL Features Typical Applications Range Up to 33 feet 10m E 932 D33TBQ Up to 16 feet 5m E 932 S16RRQ For indoor use 12 18VDC Horizontal and vertical adjustment for easy alignment N C N O COM relay outputs Entry detection for store fronts Alarm sensor Use of this sensor in certain security applications may be regulated by local laws or codes SECO...

Страница 2: ... Mounting Screws Be sure to use flat head flush mounting screws Fig 4 Wiring Fig 2 Sample Installations Fig 3 Mounting Green N O Blue N C White COM Red DC Black DC RX Red DC Black DC TX E 932 D33TBQ E 932 S16RRQ RX TX Green N O Blue N C White COM Red DC Black DC ...

Страница 3: ... or warning device 2 Replace the lens covers on the transmitter receiver Test again one last time E 932 D33TBQ Installation and Alignment LED functions TX RED on Power RX RED off Aligned RX RED on Out of Alignment RX RED on after being aligned Unit Triggered Installation 1 Decide where to mount a The transmitter and receiver should be facing each other b The units should not interfere with normal ...

Страница 4: ... service for a period of one 1 year from the date of sale to the original consumer customer SECO LARM s obligation is limited to the repair or replacement of any defective part if the unit is returned transportation prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal ...

Отзывы: