background image

3

E-932-S16RRQ

Installation and Alignment

LED functions:

Red (on): Power
Yellow (off): Aligned
Yellow (on): Out of Alignment
Yellow (on) after being aligned: Unit Triggered

Installation:

1. Decide where to mount:

a. The reflector should be directly across from

the transmitter/receiver.

b. The unit should not interfere with normal

movement around the protected area.

2. Wire the unit - Run the wires to the back box

where the sensor is to be mounted.  Keep
wires hidden where possible, and expose them
only at the very end where needed to connect
to the transmitter/receiver. (see fig.4)

3. Mount the transmitter/receiver (flush mount)

(fig. 3) - Mount flush to the wall with two
mounting screws.

4. Initial test - Temporarily hold the reflector to the

wall and power up the unit to test alignment
before permanent mounting. (See Power and
Alignment below.)

Power and Alignment:

1. Power up the transmitter/receiver. The red LED

will turn ON to indicate power is present.  The
yellow LED on the unit will turn OFF to indicate
they are aligned properly.

2. Alignment - If the unit is connected to power,

and the yellow LED does not turn off while the
red LED is on, the unit and reflector are not
aligned.  Adjust the unit on its pivot points until
the yellow LED turns off, indicating alignment.
(Fig. 1.)

Testing:

1. Do a walk-through test. Walk between the

transmitter/receiver and the reflector. This
should break the beam, turn the yellow LED
on, and trigger the alarm panel or warning
device.

2. Replace the lens covers on the transmitter/

receiver. Test again one last time.

E-932-D33TBQ

Installation and Alignment

LED functions:

TX RED (on): Power
RX RED (off): Aligned
RX RED (on): Out of Alignment
RX RED (on) after being aligned: Unit Triggered

Installation:

1. Decide where to mount:

a. The transmitter and receiver should be

facing each other.

b. The units should not interfere with normal

movement around the protected area.

2. Wire the units - Run the wires to the back

boxes where the sensors are to be mounted.
Keep wires hidden where possible, and
expose them only at the very end where
needed to connect to the transmitter and
receiver. (see fig.4)

3. Mount the transmitter and receiver (flush

mount) (fig. 3) - Mount flush to the wall with two
mounting screws each.

4. Initial test - Power up the units to test alignment

before permanent mounting. (See Power and
Alignment below.)

Power and Alignment:

1. Power up the transmitter and receiver. The red

LED on the transmitter should turn ON to
indicate power is present. The red LED on the
receiver should turn OFF to indicate the two
are aligned properly.

2. Alignment - If the receiver is connected to

power, and if the red LED does not turn off
while the receiver is on, the transmitter and
receiver are not aligned. Adjust the units on
their pivot points until the red LED on the
receiver turns off, indicating alignment. (Fig. 1.)

Testing:

1. Do a walk-through test. Walk between the

transmitter and receiver. This should break the
beam, turn the red LED on, and trigger the
alarm panel or warning device.

2. Replace the lens covers on the transmitter and

receiver. Test again one last time.

Содержание E-932-D33TBQ

Страница 1: ...ty of explosive gasses being present INSTALLATION MANUAL Features Typical Applications Range Up to 33 feet 10m E 932 D33TBQ Up to 16 feet 5m E 932 S16RRQ For indoor use 12 18VDC Horizontal and vertical adjustment for easy alignment N C N O COM relay outputs Entry detection for store fronts Alarm sensor Use of this sensor in certain security applications may be regulated by local laws or codes SECO...

Страница 2: ... Mounting Screws Be sure to use flat head flush mounting screws Fig 4 Wiring Fig 2 Sample Installations Fig 3 Mounting Green N O Blue N C White COM Red DC Black DC RX Red DC Black DC TX E 932 D33TBQ E 932 S16RRQ RX TX Green N O Blue N C White COM Red DC Black DC ...

Страница 3: ... or warning device 2 Replace the lens covers on the transmitter receiver Test again one last time E 932 D33TBQ Installation and Alignment LED functions TX RED on Power RX RED off Aligned RX RED on Out of Alignment RX RED on after being aligned Unit Triggered Installation 1 Decide where to mount a The transmitter and receiver should be facing each other b The units should not interfere with normal ...

Страница 4: ... service for a period of one 1 year from the date of sale to the original consumer customer SECO LARM s obligation is limited to the repair or replacement of any defective part if the unit is returned transportation prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal ...

Отзывы: