                                          ENFORCER 50ft Reflective Photoelectric Beam Sensor 

 

SECO-LARM U.S.A., Inc.                                                                                     

 

 

1.

 

Mount the sensor and reflector so that they face 
each other. 

2.

 

Connect power to the sensor. The LED will light 

as indicated in the chart below. 

3.

 

Unscrew the four cover screws and remove the 
cover. 

4.

 

To find the correct alignment, slowly turn the 
lens assembly left and right to adjust the 

horizontal angle. 

5.

 

Loosen the vertical adjustment screw to adjust 
the vertical angle. 

6.

 

Place the hood on the sensor by sliding the 
hood’s ridges into the slots on the sides of the 

sensor. 

7.

 

Re-attach the cover, replace the four screws, 
and attach the hood to the top of the sensor. 

1.

 

Unscrew the four cover screws and remove the 
cover. 

2.

 

Loosen the captive screw and remove the sensor 
from the mounting plate. 

3.

 

Using the included mounting screws, mount the 
mounting plate to the wall. 

4.

 

Use the cable breakout and cable connector at 
the bottom or rear of the sensor to run the wires. 

5.

 

Hang the sensor back on the plate and use the 

captive screw to secure it in place. 

6.

 

Re-attach the cover, replace the four screws, and 
attach the hood to the top of the sensor. 

Mounting: 

Alignment: 

Solid green 

Good beam signal, 

properly aligned 

Alternating flash 

Poor beam signal 

Solid red 

No beam signal, 

triggered 

 

Lens 

alignment 

±90

 

±5

 

Horizontal 

adjustment 

Vertical 

adjustment 

Wiring for the Bottom Cable Breakout 

1.

 

Puncture the cable breakout located at the bottom 

of the sensor using a screwdriver or other object. 

2.

 

Insert the short end side of the cable connector 
into the cable breakout hole and use the nut to 

secure it, tightening with a wrench as needed. 

3.

 

Run the wires through the end cap and cable 
connector. 

4.

 

Then screw the end cap into the external side of 
the cable connector to prevent water from 

entering the unit. 
 

Cable 
Connector 

End cap 

Sensor 

Nut 

Rubber 

neck 

Содержание E-931-S50RRGQ

Страница 1: ...AC VDC Beam status LED N C Tamper switch 500mA 30VAC VDC Caution This sensor is not designed to prevent bodily injury or loss of life This sensor is not designed for use in environments where explosive gasses may be present Use of this sensor in certain security applications may be regulated by local laws or codes SECO LARM is not responsible for compliance with such laws or codes ...

Страница 2: ...tor mounting screw 1x Rubber ring 1x Cable connector 1x Manual 1x Removable terminal block 1x 10KΩ Resistor Overview Tamper switch Vertical adjustment screw without cover Cover Cover screw Wire cable connector Mounting plate Hood Dimensions Beam sensor LED Terminal block Cable breakout Captive screw Beam sensor 413 16 122mm 3 16 4mm 31 4 82mm 3 8 9mm 21 8 54mm 23 8 60mm 115 16 49mm 27 16 62mm Cabl...

Страница 3: ...mount the mounting plate to the wall 4 Use the cable breakout and cable connector at the bottom or rear of the sensor to run the wires 5 Hang the sensor back on the plate and use the captive screw to secure it in place 6 Re attach the cover replace the four screws and attach the hood to the top of the sensor Mounting Alignment Solid green Good beam signal properly aligned Alternating flash Poor be...

Страница 4: ...the time of publication However the SECO LARM policy is one of continual development and improvement For this reason SECO LARM reserves the right to change specifications without notice SECO LARM is also not responsible for misprints or typographical errors Copyright 2016 SECO LARM U S A Inc All rights reserved This material may not be reproduced or copied in whole or in part without the written p...

Отзывы: