a. MODE 

SWITCH 

 

  

 

 

 

When the mode switch is pressed,  the stove will automatically ignite.  If the manual mode is selected, the heat level must be selected 
manually to adjust the stove’s heat output to the desired level.  If the thermostat mode is selected, the stove will automatically modulate 
between the lowest heat level and the heat level selected to keep the room temperature at the thermostat’s setting. If the set room 
temperature is achieved  while the stove has been running at the lowest heat level for more than 45 minutes, the unit will automatically 
shut off and will start another ignition cycle only when the thermostat calls for heat again.  No  fire starter is necessary to ignite the unit. 
The auger will feed fuel for 4 minutes and the electronic igniter will stay on for 10 minutes.  If  the unit doesn’t ignite within 15 minutes, 
the stove will wait for 5 minutes and will start a second ignition cycle. If  ignition fails a second time, a warning message will appear on 
control panel. 

 

 

The Heat Level may be selected during the ignition cycle. However, the unit will only feed fuel at the desired heat level setting when the 
heat sensor located into the stove will receive a signal indicating that the unit has been fully ignited.  This may  take anywhere between 
10 and 15 minutes. 

 

b. 

FUEL FEED SWITCH  

 

 

 

When the “Fuel Feed” button is pushed and held down the stove will feed pellets continuously into the burn pot. 

 

CAUTION:

 THIS FUNCTION CAN ONLY BE OPERATED WHEN THE STOVE IS IN “OFF” POSITION.  THE FUEL FEED SWITCH IS 

USED TO PRIME THE AUGER WHEN AUGER IS EMPTY. 

 

c. 

NOISE REDUCER  

 

 

 

The convection blower speed varies directly with the fuel feed rate. 

 

When the “NOISE REDUCER” button is pushed, the convection blower will switch to its lowest speed. The convection blower will 
remain at its lowest speed unless the stove reaches a certain temperature.  If this occurs, the convection blower will go back to its 
highest setting to cool down the stove.  The low noise button will have to be pressed again for the convection blower to go back to its 
lowest speed. The functions normally activated by this icon are not available on this specific model. However, the icon could be used to 
access certain troubleshooting or programming functions. 

 

d. 

HEAT LEVEL  

 

 

 

By pressing “+” or “-“, you can set the pellet feed rate and hence the heat output of your stove. The levels of heat output will 
incrementally change and each LED indicate the level from 1 to 6. 

 

e. RESET 

 

 

 

Reset button has to be used to clear any error on the control and restart your stove. 

 

 
OPENING DOOR

 

 
The door should be open only for maintenance purposes. 
 

 
CONVECTION BLOWER (ROOM AIR FAN)

 

 
Upon starting your stove, the convection blower will not come on until the stove’s heat exchanger warms up. This usually takes about 10 to 
15  minutes from start-up.  Speed will vary with the selected feed rate, except if the noise reducer mode has been activated. 
 
 

COMBEX

tm

 

 

Your stove uses a unique patented technology called COMBEX.  As opposed to most other pellet stoves, which use 
only an exhaust blower, your BIO-45MF uses a motor on which are mounted two housings with impeller blades. One 
housing serves for combustion, and the other for exhaust. This is why we refer to the combustion/exhaust blower 
throughout this manual. The COMBEX system balances combustion air and uptake to provide clean, worry-free 
combustion which is less dependent on the leak-tightness of the device and the quality of the combustible. 
 

OPERATION

15

Содержание BIO-45 MF

Страница 1: ...e hot at higher feeding rates To prevent potential burns avoid contact with those areas This heating unit must serve as a supplementary heat source An alternative heat source should be available in the home if needed The manufacturer cannot be responsible for additional heating costs associated with the use of an alternative heat source It is highly recommended that the user buys this product from...

Страница 2: ...by WETT Wood Energy Technical Training or in Quebec by APC Association des Professionnels du Chauffage This appliance is designed specifically for use only with pelletized wood It is designed for residential installation according to current national and local building codes as a freestanding room heater It is also approved as a mobile home heater which is designed for connection to an outside com...

Страница 3: ...rise to operational levels one of the sensors could then make the stove start on its own It is recommended that the stove be unplugged when not in use for extended amounts of time i e during the summer months Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirements in your area Notify your insurance company of this stove a...

Страница 4: ...llation 17 Please Read This Operating Safety Precautions 17 MAINTENANCE 20 Ash Removal 20 Ash Disposal 20 Vacuum Use 21 Cleaning 21 Blowers 21 Chimney Cleaning 22 Recommended Maintenance Schedule 22 Removal Replacement of Broken Door Glass 22 TROUBLE SHOOTING GUIDE 23 ELECTRICAL DIAGRAM 29 REPLACEMENT PARTS LIST APPENDIX A APPENDIX B 30 31 32 WARRANTY 33 TABLE OF CONTENTS 4 REGISTER YOU WARRANTY O...

Страница 5: ... In Canada the unit must be installed on a noncombustible floor pad extending at least 18 inches 460 mm in front of the door opening and at least 8 inches 205 mm at the back and on each side of the unit The floor pad must have a thickness of at least 0 015 0 38mm NOTE ceramic tile or any tile must be laid on a continuous non combustible sheet to prevent the possibility of embers falling through to...

Страница 6: ...hat meets the ULC S 609 M89 and ULC ORD C441 M90 Standards For the United States we recommend that you use a listed pellet vent that meets the UL 641 7 th edition Standard This unit can be vented in an existing chimney with the addition of a liner if the chimney is more than 4 in diameter Class A chimney is not required Refer to the instructions provided by the vent or chimney manufacturer especia...

Страница 7: ...ulate the EVL of your installation See Figure 8 3 x 4 of vertical length 12 x 0 5 6 EVL 1 x elbow or T 5 EVL 2 x 1 of horizontal length 2 EVL Total EVL 6 5 2 13 So 3 diameter vent is acceptable Note Do not count the outside termination goose neck in the EVL calculation INSTALLATION CONFIGURATIONS Termination Location Termination should not be located so that hot exhaust gases can be a hazard They ...

Страница 8: ... 213 cm Clearance above paved side walk or a paved driveway located on public property 39 100 cm Clearance to property boundary A vent shall not terminate underneath a veranda porch or deck United States Not Less than 36 91 cm above any forced air inlet located within 10 feet 305 cm Not Less than 48 122 cm below and horizontally from or one foot 30 cm above any door window or gravity air inlet int...

Страница 9: ...he pipe from the exhaust outlet to the rear center of the stove OPTION Install Vent elbow in place of clean out tee Locate stove Drop plumb bob to center of tee outlet mark point on ceiling Install ceiling support and Vent pipe per Vent manufacturer s instructions 1 Always maintain 3 clearance from combustible materials When passing through additional floors or ceilings always install firestop spa...

Страница 10: ... preferred method Follow guidelines for equivalent vent length BASEMENT INSTALLATION CLEAN OUT TEE FOR BASEMENT INSTALLATION A 4 PIPE IS RECOMMANDED FOLLOW CHIMNEY OR VENT MANUFACTURER S INSTRUCTIONS CLEAN OUT TEE WALL STRAP FIGURE 9 Venting through roof FIGURE 11 Venting through existing chimney FIGURE 10 Basement installation INSTALLATION 10 ...

Страница 11: ... the center of the hole where the pipe is to pierce the masonry chimney 2 It will be necessary to break out the masonry around the location of the pipe center mark Use a 4 inch diameter hole for 3 inch pipe and 5 inch diameter hole for 4 inch pipe 3 Measure and build chimney top plate Cut out holes for chimney pipe and if used the outside air pipe 4 Install the tee on the bottom of the vertical pi...

Страница 12: ...came with your owner s manual Fix the two brackets using the same screws you have removed Lay the log set inside the firebox as shown on figure 14d 14e SCREWS SCREWS LOG SUPPORTS LOG SUPPORT LOG SUPPORT LOG SET LOG SUPPORT Figure 14c Location of supports Figure 14d Log set positionning Figure 14e Log set positionning Figure 14b Log set supports Figure 14a Fixation of supports INSTALLATION 12 ...

Страница 13: ...at they are cleaned on a regular basis as per our recommended maintenance schedule This is particularly critical if you have animals in your house such as a dog or a cat Filters that are not cleaned can clog up and cause your stove to overheat You may also damage or burn the convection blowers In order to install the filters simply insert them in the slot just above the blower s finger guard To cl...

Страница 14: ...nd ash content should be indicated on the bag by the pellet manufacturer PRE START UP CHECK Remove burn pot making sure it is clean and none of the air holes are plugged Clean the firebox and then reinstall burn pot Clean door glass if necessary a dry cloth or paper towel is usually sufficient Never use abrasive cleaners on the glass or door Check fuel in the hopper and refill if necessary BUILDIN...

Страница 15: ...with the fuel feed rate When the NOISE REDUCER button is pushed the convection blower will switch to its lowest speed The convection blower will remain at its lowest speed unless the stove reaches a certain temperature If this occurs the convection blower will go back to its highest setting to cool down the stove The low noise button will have to be pressed again for the convection blower to go ba...

Страница 16: ...CEDURE Turning your Enerzone stove off is a matter of pressing the MODE control panel switch until the OFF led goes on The blowers will continue to operate until internal firebox temperatures have fallen to a preset level SAFETY FEATURES a Your stove is equipped with a re settable high temperature switch also called heat sensor or heat switch The switch has a reset button on its backside Like a ci...

Страница 17: ...n the best comfort and efficiency from you BIO 45 MF The thermostat should be mounted 50 inch from the floor on a wall located 15 to 20 feet from the stove You should avoid an installation directly in front of the stove to avoid cycling See figure 17 MODES THERMOSTATIC MODE To use this mode the MODE button must be pushed to Thermostat upon starting the stove The heat setting is then selected using...

Страница 18: ...that the letters P I L O T O N will appear on the PC Board to let you know that you are in the PILOT ON mode If you wish to go back to the default thermostatic mode i e the unit shuts down after 45 minutes if the thermostat does not call for heat simply press the same two buttons again for a couple of seconds The letters P I L O T A U T O will appear on the PC Board to let you know that you are in...

Страница 19: ...he ambient air in a confined room becomes to hot the stove may overheat and the thermal protection on the combustion exhaust motor may be activated causing the motor to stop d KEEP ALL LOOSE OR MOVEABLE HOUSEHOLD COMBUSTIBLES SUCH AS FURNITURE DRAPES TOYS ETC AT LEAST THREE FEET FROM THE OPERATING STOVE e Maintain proper ventilation It is important that adequate oxygen be supplied to the fire for ...

Страница 20: ...d Open the door and remove the burn pot by grasping it and pulling straight out Scrape the burn pot with a scraper if necessary Make sure that the burn pot holes are not plugged Empty ashes from the burn pot into the pedestal ash bin through the opening at the bottom of the firebox Put the burn pot back in place Make sure it is level and pushed all the way in e Scrape the ashes in the firebox into...

Страница 21: ... outlet and clean thoroughly REPEAT THIS OPERATION AT LEAST ONCE PER TON OF PELLETS BURNED UNTIL YOU ARE FAMILIAR WITH HOW ASHES ACCUMULATE WITH YOUR OPERATING PRACTICES BLOWERS DANGER RISK OF ELECTRIC SHOCK DISCONNECT POWER BEFORE SERVICING UNIT Cleaning Over a period of time ashes or dust may collect on the blades of both the combustion exhaust blower and convection blower Periodically the blowe...

Страница 22: ...ied chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally inspected cleaned and if necessary repaired To clean the chimney detach the vent at the combustion blower transition where it is attached to the blower RECOMMENDED MAINTENANCE SCHEDULE Use this as a guide under average use conditions Components Daily Weekly or after...

Страница 23: ...ed Check to make sure vent pipe installation meets the criteria in the owner s manual as well as the pipe manufacturer s recommendations 4 The airflow pressure switch wire connections are faulty Check the connectors attached to the pressure switch 5 The airflow pressure switch wires are pulled loose at the connector on the wiring harness Check to see whether the wires are loose at the connectors 6...

Страница 24: ...aft from the auger housing Start by emptying the hopper Take the rear panel off the stove body Then take the auger motor off by removing the screws that hold the motor to the auger shaft Once the motor is out remove the four screws on the steel plate that holds the auger shaft to the auger housing Then rotate the bottom end of the auger shaft down towards you until you can pull the shaft down out ...

Страница 25: ...ensor is bad the unit will stop after the ignition cycle If this situation occurs call your dealer or technician 5 The control board is not sending power to the igniter Check the voltage going to the igniter during ignition It should be a full current If the voltage is lower than full current check the wiring If the wiring is functional and properly connected the board is defective You will need a...

Страница 26: ...gain SMOKE SMELL COMING BACK INTO THE HOME Possible Causes Possible Remedies 1 There is a leak in the vent pipe system Inspect all vent pipe connections This is a pressurized exhaust system All vent connector joints must be sealed and fastened in accordance with the pellet pipe manufacturer s instructions to ensure consistent performance and avoid smoke and ash spillage 2 The gasket on the combust...

Страница 27: ...mately 3000 RPM You will need a technician to perform this test 7 Bad pellets Applies to GLASS SOOTS UP AT A VERY FAST RATE Only The brand of pellets or the batch of pellets that are being used may be of poor quality If possible try a different brand of pellets You might also want to try a brand that is made from a different type of wood softwood vs hardwood Different woods have different characte...

Страница 28: ...pper lid stay open more than 3 minutes Inverted polarity in power outlet Power outage Igniter fuse is burnt out SMOKE SMELL OR SOOT BUILD UP Because it is a wood burning device your BIO 45 MF may emit a faint wood burning odor If this increases beyond normal or if you notice an unusual soot build up on walls or furniture check your exhaust system carefully for leaks All joints should be properly s...

Страница 29: ...WER HIGH TEMPERATURE HIGH TEMPERATURE HIGH TEMPERATURE SWITCH L 250 AUTOMATIC CONTROL FRESH AIR INTAKE CONVECTION BLOWER AIR SUPPLY SWITCH L 250 MANUAL RESET SWITCH F 160 COMBUSTION EXHAUST BLOWER MOTOR THERMISTOR EXHAUST IGNITER PRESSURE SWITCH CONVECTION BLOWER AUGER MOTOR AIR SUPPLY CONTROL POWER CORD THERMOSTAT TERMINAL CONVECTION BLOWER HIGH TEMPERATURE SWITCH L 250 MANUEL RESET CLEANING ACCE...

Страница 30: ...039 Convection Blower 44040 Door Gasket AC06000 Door Glass Center SE52707 Log support PL52691 Exhaust Adapter 3 SE52572 Hot Rod Igniter 44030 Thermistor 44095 F 160 Convection blower heat sensor 44058 L 250 Automatic High Temp Switch 44059 L 250 Manual Reset High Temp Switch 44041 Window Gasket 7 AC06400 Convection blower gasket 21107 Combustion Exhaust blower gasket 21109 Auger 24017 Loading lid ...

Страница 31: ...tal vent coming out at the back of the stove on a total distance of 4 feet followed by a Tee and a 6 foot vertical rise it would be acceptable The installation would end be within the allowable configuration zone on the chart since it would have at least one foot of vertical rise for each foot of horizontal run Furthermore the total vertical rise would be at least 3 foot high WARNING To reduce the...

Страница 32: ...ivalent vent lenght calculation table DRAW YOUR INSTALLATION 1 SQUARE 1 F00T PART DAILY 10 bags 25 bags E xchanger Baffle Left interior channel Hopper Evacuation blower Blower blades Pressure system Burn pot Convection blower filter Evacuation system Gaskets CLEANING Use 4 pipe if you have more than 15 feet of Equivalent Vent Length EVL The longer the run of pipe in your installation the more rest...

Страница 33: ...costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding the wholesale price of any warranted but defective parts The manufacturer shall i...

Отзывы: