background image

Step 2: Preparation of exodraft fan

 

y

Locate the installation brackets in the slots going through the fan 

base part, using the bolts and nuts supplied to secure

 

the brackets. If 

the flue diameter is larger than the chimney fan inlet, the bracket can 

be installed underneath the base part. Note that the bolts must be 

installed from the

 

bottom side.

 

y

 Adjust the final position of the installation brackets ensuring that

 

there is a small gap between the brackets and the flue wall/adapter

 

throat. 

 

y

Tighten the nuts. If the brackets touch the flue wall, it

 

may create 

some vibration noise.

Step 3: Attaching the fan

 

y

The chimney fan is now ready for installation on the top of the

 

chim-

ney.

 

y

Place the fiber mat with the aluminum foil facing

 

upwards on the top 

of the adapter, and place the fan on top

 

of the mat. 

 

y

High temperature silicone can be applied on the

 

side of the mat, but is 

not required. 

 

y

It can also be painted. It

 

is not necessary to bolt the fan to the chim-

ney.

Step 4: Sealing the slots

 

y

To avoid rainwater to enter the chimney the 4 slots must be sealed with silicone.

CAUTION

Under conditions with extremely strong winds surrounding the top 

of the chimney, the chimney fan must be secured by steel wires 

               supplied with the fan.

3.4 Single fan on brick chimney

Step 1: Prepare fan location

 

y

The installation procedure is the same whether the flue is round 

or

 

square. If a clay tile flue liner is installed, it might stick up a few

 

inches.

 

Cut it back so it is flush with or no more than 1/2 inch above

 

the chimney crown.

 

y

Measure the inside diameter of the flue, cut a corresponding hole in

 

the fiber mat leaving a minimum distance of 3/4” to any side of

 

the 

fiber mat.

 

y

The aluminum foil on the fiber mat must face upwards (against fan

 

base).

Step 2: Preparation of fan

 

y

Locate the installation brackets in the slots going through the fan 

base part, using the bolts and nuts supplied to secure

 

the brackets. 

If the flue diameter is larger than the chimney fan inlet, the bracket 

can be installed underneath the base part. Note that the bolts must 

be installed from the

 

bottom side.

 

y

Adjust the final position of the brackets ensuring that there is

 

clear-

ance between the brackets and the flue wall.

 

If the brackets

 

touch 

the wall, it may generate some vibration noise.

7

3100153 RSHT009 - 016 2012-11-15

Содержание RSHT009-016

Страница 1: ...formation Chapters 1 2 Mechanical installation Chapter 3 Electrical installation Chapter 4 Start up and configuration Chapter 5 Maintenance and troubleshooting Chapter 6 READ AND SAVE THESE INSTRUCTIO...

Страница 2: ...g eration and Air Conditioning Engineers ASHRAE and the local code authorities 5 This unit must be grounded How to use this manual This installation manual does not contain any system design documenta...

Страница 3: ...must be in accordance with the requirements of authority having jurisdiction or in the absence of such requirements with the National Electrical Code NFPA70 1 2 Shipping The packing list attached to...

Страница 4: ...41 9 47 2 kg 11 6 15 2 19 0 21 4 Dimensions A in 11 7 12 8 14 6 15 7 mm 298 325 372 400 B x B in 11 7 14 3 16 6 18 8 mm 296 364 422 478 C in 10 8 13 5 15 6 17 4 mm 275 344 395 441 D in 3 0 3 3 3 9 3...

Страница 5: ...the fan should be secured by wires attached on the chim ney and on the roof at 2 to 3 different points Brick chimneys usually do not need any kind of support to carry the weight of the chimney fan Sy...

Страница 6: ...must be removed The steel chimney adapter SCA slides right into the chimney where the long collar engage ment ensures safe anchoring If necessary the adapter can be secured by means of long self tappi...

Страница 7: ...s must be sealed with silicone CAUTION Under conditions with extremely strong winds surrounding the top of the chimney the chimney fan must be secured by steel wires supplied with the fan 3 4 Single f...

Страница 8: ...4 GA or thicker y y When installing multiple fans it is extremely important that the fans are of the same model and size and they must be controlled in tandem by one 1 motor speed control 3 6 Multiple...

Страница 9: ...Hz 3 50 Amps y y RSHT016 1 x 120 V 60 Hz 4 50 Amps The exodraft chimney fans have a split capacitor motor with infinitely variable speed The fan speed control supplied is rated 1 x 120 V 60 Hz and 5 A...

Страница 10: ...N FAN MOTOR WEATHERPROOF BOX WEATHERPROOF BOX L 4 4 Connection and wiring diagram for single fan with EFC211 The diagrams below show the wiring of a single chimney fan when used in conjunction with an...

Страница 11: ...Most pizza ovens consist of a dome with a front opening that can be closed with a cast iron door Above the opening a hood connected to the flue as sures smoke and odors are collected and removed safel...

Страница 12: ...iod of time CAUTION Do not over fire the fireplace stove or pizza oven Small deposits of creosote could be ignited and start a small chimney fire which could cause the chimney flue to reach a dangerou...

Страница 13: ...g out D Unscrew and remove the 1 4 bolt at the end of the vane pipe axle A B C D E Use a 3 8 bolt min length 5 5 to draw the wheel of the motor axle E Replace Motor F Loosen the cable gland G Remove t...

Страница 14: ...an speed control is off Bad electrical connections Check the circuit breaker Turn fan speed control on Check and correct problem There is power to the fan but it is not operating Bad electrical connec...