background image

3. Mechanical installation 

3.1 Transport safety device

Remove the transport safety device  from the vane and

 

make sure that the vane can revolve without hindrance.

3.2 Prior to operation

To open the fan: Remove the two nuts 

at the front and pull out the lock pin at 

the rear of the fan. 

Too secure the fan in open position 

place the lock pin in the bracket again.

Always mount the fan in vertical 

position.

DO NOT MOUNT HORIZONTALLY

              

3.3 Single fan on steel chimney

Step 1: Prepare fan location

 

y

If a stack cap is already installed, it must be removed.

 

The steel

 

chimney 

adapter (SCA) slides right into the chimney, where the long

 

collar engage-

ment ensures safe anchoring.

 

If necessary,

 

the adapter can be secured by 

means of long self-tapping stainless

 

steel screws into the side of the collar 

through the chimney wall.

If the steel chimney is air cooled, a special adapter for such 

chimney must be used.

 

y

Measure the inside diameter of the flue and cut a corresponding hole

 

in the 

center of the fiber mat.

 

If the flue is so big that the throat in

 

the adapter has 

been reduced to fit the throat of the fan, the hole in

 

the fiber mat should cor-

respond to the throat.

 

 

y

The aluminum foil on the fiber mat must face upward (against fan

 

base).

6

3100153 RSHT009 - 016 2012-11-15

Содержание RSHT009-016

Страница 1: ...formation Chapters 1 2 Mechanical installation Chapter 3 Electrical installation Chapter 4 Start up and configuration Chapter 5 Maintenance and troubleshooting Chapter 6 READ AND SAVE THESE INSTRUCTIO...

Страница 2: ...g eration and Air Conditioning Engineers ASHRAE and the local code authorities 5 This unit must be grounded How to use this manual This installation manual does not contain any system design documenta...

Страница 3: ...must be in accordance with the requirements of authority having jurisdiction or in the absence of such requirements with the National Electrical Code NFPA70 1 2 Shipping The packing list attached to...

Страница 4: ...41 9 47 2 kg 11 6 15 2 19 0 21 4 Dimensions A in 11 7 12 8 14 6 15 7 mm 298 325 372 400 B x B in 11 7 14 3 16 6 18 8 mm 296 364 422 478 C in 10 8 13 5 15 6 17 4 mm 275 344 395 441 D in 3 0 3 3 3 9 3...

Страница 5: ...the fan should be secured by wires attached on the chim ney and on the roof at 2 to 3 different points Brick chimneys usually do not need any kind of support to carry the weight of the chimney fan Sy...

Страница 6: ...must be removed The steel chimney adapter SCA slides right into the chimney where the long collar engage ment ensures safe anchoring If necessary the adapter can be secured by means of long self tappi...

Страница 7: ...s must be sealed with silicone CAUTION Under conditions with extremely strong winds surrounding the top of the chimney the chimney fan must be secured by steel wires supplied with the fan 3 4 Single f...

Страница 8: ...4 GA or thicker y y When installing multiple fans it is extremely important that the fans are of the same model and size and they must be controlled in tandem by one 1 motor speed control 3 6 Multiple...

Страница 9: ...Hz 3 50 Amps y y RSHT016 1 x 120 V 60 Hz 4 50 Amps The exodraft chimney fans have a split capacitor motor with infinitely variable speed The fan speed control supplied is rated 1 x 120 V 60 Hz and 5 A...

Страница 10: ...N FAN MOTOR WEATHERPROOF BOX WEATHERPROOF BOX L 4 4 Connection and wiring diagram for single fan with EFC211 The diagrams below show the wiring of a single chimney fan when used in conjunction with an...

Страница 11: ...Most pizza ovens consist of a dome with a front opening that can be closed with a cast iron door Above the opening a hood connected to the flue as sures smoke and odors are collected and removed safel...

Страница 12: ...iod of time CAUTION Do not over fire the fireplace stove or pizza oven Small deposits of creosote could be ignited and start a small chimney fire which could cause the chimney flue to reach a dangerou...

Страница 13: ...g out D Unscrew and remove the 1 4 bolt at the end of the vane pipe axle A B C D E Use a 3 8 bolt min length 5 5 to draw the wheel of the motor axle E Replace Motor F Loosen the cable gland G Remove t...

Страница 14: ...an speed control is off Bad electrical connections Check the circuit breaker Turn fan speed control on Check and correct problem There is power to the fan but it is not operating Bad electrical connec...

Страница 15: ...Notes 15 3100153 RSHT009 016 2012 11 15...

Страница 16: ...SA Canada ENERVEX Inc 1685 Bluegrass Lake Parkway Alpharetta GA 30004 P 770 587 3238 F 770 587 4731 T 800 255 2923 info enervex com www enervex com www exodraft com Volko Supply www chimneyfansource c...