3. Mechanical installation
3.1 Transport safety device
Remove the transport safety device from the vane and
make sure that the vane can revolve without hindrance.
3.2 Prior to operation
To open the fan: Remove the two nuts
at the front and pull out the lock pin at
the rear of the fan.
Too secure the fan in open position
place the lock pin in the bracket again.
Always mount the fan in vertical
position.
DO NOT MOUNT HORIZONTALLY
3.3 Single fan on steel chimney
Step 1: Prepare fan location
y
If a stack cap is already installed, it must be removed.
The steel
chimney
adapter (SCA) slides right into the chimney, where the long
collar engage-
ment ensures safe anchoring.
If necessary,
the adapter can be secured by
means of long self-tapping stainless
steel screws into the side of the collar
through the chimney wall.
If the steel chimney is air cooled, a special adapter for such
chimney must be used.
y
Measure the inside diameter of the flue and cut a corresponding hole
in the
center of the fiber mat.
If the flue is so big that the throat in
the adapter has
been reduced to fit the throat of the fan, the hole in
the fiber mat should cor-
respond to the throat.
y
The aluminum foil on the fiber mat must face upward (against fan
base).
6
3100153 RSHT009 - 016 2012-11-15
Содержание RSHT009-016