The Dry Fluid Cooler is used to remove heat 

from the heat pump heat transfer fluid.  Two 

configurations are possible with the unit; outdoor 

air only, or hybrid operation with the Fluid Cooler 

in parallel with the Ground Loop, except in certain 

applications (See Section 4 for more details).

Notices, Cautions, Warnings, & Dangers 

“NOTICE” 

Notification of installation, operation or 

maintenance information which is important, but 

which is NOT hazard-related.

“CAUTION” 

Indicates a potentially hazardous 

situation or an unsafe practice which, if not 

avoided, COULD result in minor or moderate injury 

or product or property damage. 

“WARNING”

 

Indicates potentially hazardous 

situation which, if not avoided, COULD result in 

death or serious injury.  

“DANGER” 

Indicates an immediate hazardous 

situation which, if not avoided, WILL result in death 

or serious injury.  

Inspection:

Upon receipt of any geothermal equipment, 

carefully check the shipment against the packing 

slip and the freight company bill of lading. Verify 

that all units and packages have been received. 

Inspect the packaging of each package and each 

unit for damages. Insure that the carrier makes 

proper notation of all damages or shortage on all 

bill of lading papers. Concealed damage should 

be reported to the freight company within 15 days. 

If not filed within 15 days the freight company can 

deny all claims.

Note: 

Notify Enertech Global, LLC shipping 

department of all damages within 15 days. It is the 

responsibility of the purchaser to file all necessary 

claims with the freight company.

Un-packaging: 

Enertech units are mounted to wooden pallets for 

easy handling during shipment and installation. 

Units are protected during shipment with durable 

cardboard corner posts, top and air coil panels. 

Shrink wrap is applied covering the entire unit and 

attachment to the pallet.

Upon receipt of the unit carefully remove the shrink 

wrap. Using a box cutter slit the shrink wrap on 

the cardboard top and corner posts. Use caution 

to not damaged the finished surface of the unit. 

Содержание SK040 series

Страница 1: ...Installation OperationsManual SK SERIES DRY FLUID COOLER REVISION REV A 20D201 01NN 20D201 01NN...

Страница 2: ...ector 6 SECTION 4 PRINCIPLES OF OPERATIONS Outdoor Air Operation 7 Hybrid Operation 7 SECTION 5 UNIT DATA INFORMATION Unit Physical Data 7 Unit Electrical Data 7 Unit Dimensional Data 8 SECTION 6 CONT...

Страница 3: ...Inspection Upon receipt of any geothermal equipment carefully check the shipment against the packing slip and the freight company bill of lading Verify that all units and packages have been received...

Страница 4: ...te Preparation Survey the installation site to determine the best location for placing the outdoor unit When possible select an exterior wall away from common living areas bedrooms family rooms etc Gr...

Страница 5: ...m any exterior wall and 32 inches from any other device Air flow should be directed away from the structure with a minimum 5 foot clearance area See below Climate Flow The flow requirements must be ve...

Страница 6: ...de of the pipe protector will sit behind the flange of the bottom pan 5 Use the two screws that were removed with the horizontal bracket to attach the top flange of the pipe protector in the same loca...

Страница 7: ...60 216 252 Fan Motor FLA Int Loop Pump FLA Total Unit FLA Min Circuit AMPS Max Fuse HACR SK040 SK060 Model Voltage Code Fan Option 60 Hz Power Outdoor Air Operation vs Hybrid Operation As stated earli...

Страница 8: ...W 46 5 22 0 24 3 29 1 4 0 6 4 3 7 4 3 38 5 23 7 8 3 5 0 2 1 POWER SUPPLY CONNECTION LOW VOLTAGE CONNECTION SOURCE WATER OUT SOURCE WATER IN SK060 Models 63 5 22 7 5 1 2 3 LOW VOLTAGE CONNECTION POWER...

Страница 9: ...circuit board When the fan is off this input is open When the fan is running in normal operation the fan alarm output is closed If the fan alarm output is open for 30 continuous seconds while the fan...

Страница 10: ...cording to the same logic as Option 1 It will also automatically perform loop cooling according to the temperature logic described in Option 2 Loop cooling is active when both of the following conditi...

Страница 11: ...X SLOW FLASH FLASH X X X FAST FLASH FLASH X SLOW FLASH X X FLASH X DIP SWITCH OPTION SELECTED 1 2 3 4 2 OPTION 1 LOOP PUMP OFF OFF OFF OPTION 2 LOOP PUMP ON OFF OFF OPTION 3 LOOP PUMP OFF ON OFF OPTI...

Страница 12: ...12 Enertech Global SK Models IOM SECTION 7 WIRING DIAGRAMS Models with Internal Loop Pump Models with Flow Switch...

Страница 13: ...Temp 3 BTUH CFM o F o F GPM o F o F o F 51 600 3 500 70 14 15 85 7 8 67 600 3 500 70 18 15 90 9 11 82 300 3 500 70 22 15 95 11 14 49 700 3 500 90 13 15 105 7 8 65 700 3 500 90 17 15 110 9 11 80 800 3...

Страница 14: ...m submitter Ifdifferent than company OTHER NOTES _______________________________________________________________________________ _______________________________________________________________________...

Страница 15: ...______________________________________________________________________ City _____________________________State Prov __________ Email ___________________________________________ Application Residential...

Страница 16: ...h product may change without notice and may not be as described herein For the most up to date information please visit our website or contact our Customer Service department at info enertechgeo com S...

Отзывы: