170 091 16 97-01
Gas burner
FAULT LOCATION GUIDE
The basis for trouble free operation can only be ensured
by the correct combined effect of the three factors:
electricity, gas flow and combustion air. Should any of
these factors change troubles may arise.
It has been proved that many troubles have rather simple
causes. Before calling the serviceman the following
checks should be made:
1. Are the gas cocks of the installation open?
2. Are the fuses in order and the current switched on?
3. Are the controls (room thermostat, boiler thermostat
etc.) correctly adjusted?
4. Is the gas pressure to the burner sufficient?
5. Is the gas relay of the burner ready for start and not
locked out?
6. Is the air supply to the burner sufficient?
To facilitate fault location we have drawn up a scheme
showing the most frequent faults in a gas burner instal-
lation and the remedies.
CAUSE
The burner does not start
No gas
No voltage
The burner motor fails to start
The gas relay is defective
Burner motor is running but no ignition after the pre-
purge time has elapsed
No voltage on the terminals
The ignition electrodes in contact with each other or with
earth
The porcelain of the electrodes is broken
Check that all gas cocks are open.
Check fuses, thermostats and electrical connections.
The thermal protection has locked out. Motor defective.
Replace
Check the contact. Replace faulty relay
Adjust
Replace the electrodes
REMEDY
1(4)
Содержание Bentone STG 146
Страница 2: ......
Страница 6: ...TECHNICAL DATA 172 215 45 98 01 DIMENSIONS OF FLANGE Flange 10 145 0 23 5 109 5...
Страница 20: ...172 305 50 97 01 GENERAL INSTRUCTIONS CONTROL OF BURNER HEAD AIRADJUSTMENT ADJUSTMENT OF INNER ASSEM BLY...
Страница 28: ......
Страница 31: ......
Страница 32: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...