171 425 77 16-01
Colour codes LMO14/24
When the burner starts, three signal lights in the reset switch indi
-
cate the normal sequence, as well as provide indication if some-
thing abnormal is happening in accordance with the following table:
Preheater in operation
Solid yellow
Ignition switched on
Flashing yellow
Normal operation
Solid green
Operation, poor lame signal
Flashing green
Undervoltage
Flashing yellow-red
Fault, alarm
Solid red
False light
Flashing red-green
Communication mode
Fluttering red
Fault codes LMO14/24
When the red light for a blocked relay box comes on, you can get
information about what has caused the problem by pressing and
holding the reset button for 3 seconds.
The number of lashes below is repeated with a pause in between.
2 lashes
No lame signal when safety time
expires
4 lashes
False light during start
7 lashes
3 x Losses of lame during opera
-
tion
8 lashes
Time-out for preheater *
10 lashes
Incorrect wiring, internal fault or
simultaneous occurrence of two
faults
*
In order for this fault code to occur, the preheater shall not
reach its cut-off temperature within 10 mins. from switch on.
To return to normal operation: Press the reset button for 1 second.
If the reset button is instead kept pressed a second time for at least
3 seconds, you can, via an interface, obtain the corresponding in-
formation on a computer or lue gas analyser.
To return to normal operation: Press the reset button for 1 second
ELECTRIC EQUIPMENT