16
6
7
9
10
11
12
13
1B
8
1A
2
5
3
4
14
Figure 12, Fixed Blade Replacement (Model EWCH90 shown, EWCH140 similar)
Key:
1A. Retaining Ring
1B. Retaining Ring
2. Spring
3. Locking Latch
4. Clevis Pin
5. Clevis Pin
6. Capscrews
7. Screws
8. Lock Washers
9. Left Side Outer Plate
10. Fixed Blade
11. Inner Plate
12. Right Side Outer Plate
13. Washers
14. Nuts
9.5.2 Moving Blade Replacement
Replace the moving blade as described in the following
steps:
1. Start the pump. Retract the piston to the home
position.
2. Stop the pump. Be sure that hydraulic pressure is
completely relieved.
3. Disconnect pump from AC power supply.
NOTICE:
WARNING
Always disconnect pump from AC
power supply before beginning cutter blade
replacement procedures. Failure to observe this
precaution could result in accidental startup as
procedures are being performed. Serious personal
injury could result.
4. Open the cutting head. Refer to Section 7.2 for
additional information.
5. Loosen and remove the moving blade screw
(Figure 13, item 1).