OPERATOR INSTRUCTION MANUAL
IM_HP_EX_Rev03_A4
HP350SMINEX; HP350DMINEX; HP550SMINEX;
HP550DMINEX; HP1000SMINEX; HP1000DMINEX
HYDRAULIC SEALED HAND PUMPS
7
3.3
HP350DMINEX, HP550DMINEX &
HP1000DMINEX INSTALLATION
AND OPERATION
The HP350DMINEX, HP550DMINEX and HP1000DMINEX
pumps have been designed for use with Equalizer maxi kit
systems; however the HP350DMINEX, HP550DMINEX and
HP1000DMINEX can be used in any situations where two
separate hydraulic systems require to be pressurised and
controlled independently by the same operator.
WARNING:
Never attempt to pressurise the
pump when the pressure gauge is not connected
or the pump is not connected to a system.
DANGER:
Always check the hydraulic system
in which the pump is to be used, is rated for
700 bar (10 000 psi). Over pressurizing a
hydraulic system will result in component failure
and personal injury.
1.
Prior to using the pump, the hydraulic gauge must be
fitted. Push the male connector on the gauges fully
into the female connector on the gauge adaptors and
rotate the locking ring counterclockwise until fully
tight.
2.
Ensure the hydraulic systems you wish to pressurise
have been bled and are free from air and leaks.
Connect the pump into the systems using the screw
connectors supplied with the pump, push the male
and female connectors together fully and rotate the
locking rings clockwise unti fully tight.
WARNING:
Never disconnect the pump or
other componnents when the system is
pressurised.
MALE AND FEMALE
CONNECTORS
LOCKING
RING
LOCKING
RING