OPERATOR INSTRUCTION MANUAL
IM_HP_EX_Rev03_A4
HP350SMINEX; HP350DMINEX; HP550SMINEX;
HP550DMINEX; HP1000SMINEX; HP1000DMINEX
HYDRAULIC SEALED HAND PUMPS
11
4.6
LONG-TERM STORAGE -
MAINTENANCE PLAN
1. Rub components down with a dry cloth to remove
moisture.
2. Coat EVERY surface and contact point with a corrosion
inhibitor. Where necessary, coat inside and outside of
component e.g. VC10
3. Nuts and threads must also be coated with a corrosion
inhibitor.
4. Once surfaces have been coated, seal individual
components in clear plastic bags or clear vacuum
bags or clear shrink wrap.
NOTE: bags/shrink wrap must be clear for visibility.
Take care when using shrink wrap that the tool is/
components are still easy to see.
5. Remove all or, where not vacuum sealed, as much air
from bags as possible.
6. Once bags have been closed and sealed DO NOT re-
open. Any visual inspections must be done with closed
and sealed bags. If bags are opened the components
will have to be dried, re-coated and re-sealed in bags/
shrink wrap.
7. Replace silica gel (100g) EVERY TIME the case is
opened.
NOTE: depending on moisture content of air, silica gel
should be changed weekly.
8. Visually inspect kits after 30-days and every 30-days
thereafter. Remember to replace silica gel before
closing case.