DIAGNOSTIC TEST (cont.)
If a situation arises where you cannot exit the diagnostic mode as described
above and the bank of 5 LED’s on the right end remain ON regardless of Program
Knob position, a combination of pushed buttons caused the control to enter a
special factory test mode. Disconnect power to reset the control to return washer
to normal operation is this occurs.
To clear latest stored error code:
Place the control into diagnostic test mode.
•Turn the program knob clockwise 9 clicks from the START position. The control will
signal
the last error code.
•Press and hold the
Options
and
Pause Cancel
buttons for 3 seconds. The code will be
cleared.
•Exit diagnostic mode to return the washer to normal operation.