www.hi-velocity.com
Refrigerant Modules (RCM-I)
The RCM-I cooling coil comes as a module and must be
installed in the horizontal position on the return air side of the
fan coil. RCM-I modules come with two L mounting brackets,
two access ports, carry-over screen and additional components
for air sealing.
Fig. 02 - Mounting brackets
Module RCM-I - RCM-I Coil Installation (2/8)
Module RCM-I
RCM-I Installation
Access Ports
When refrigerant lines are connected to the RCM-I coil, high
and low side access ports must be connected as well. (Fig. 01 -
reference 2 & 6) With the use of a tee and reducer this process is
simplified. The access ports are required for system startup and
for future trouble shooting or service. When reading refrigerant
pressures/temperatures, always read them at the evaporator
access ports.
RCM-I modules can be used on any R-410A condenser if
R-410A refrigerant components are used. All Energy Saving
Products R-Series modules come standard with R-410A
refrigerant components.
This module is for use with HVS-36 and HVS-60 Inverter
Heat Pump Condensing Units. It does not come with thermal
expansion valve, as there are internal EXVs inside the Heat
Pump. When installing the RCM-I Modules,
DO NOT INSTALL
WITH TXVs.
The module will come with access ports that will need to
be installed to read refrigerant pressures/temperatures at the
Evaporator (RCM-I). Fig. 01 shows approximate installation
locations for these components.
RCM-I Modules were designed to be used with the HVS-
36 and HVS-60 Heat Pumps but can be used on any R-410A
Condensing Unit, as long as a TXV is installed as well. All Energy
Saving Products cooling modules come standard with R-410A
refrigerant components.
1) Liquid line
2) High side access port
3) Refrigerant distributor
4) Distributor tubes
5) Suction line
6) Low side access port
7) Suction line temperature port
8) Middle coil temperature port
1
2
3
4
5
6
7
7
Mounting Brackets
Mounting the cooling coil to the fan coil can be done with
the L brackets supplied (Fig. 02), ensure that no screws puncture
the drain pan or coil. Page 8 has the dimensions of the cooling
modules.
Note: 7 & 8 coil temperature ports are explained in Module HVS - Heat Pump Manual