Rev 08/24/10
ENERGY KING™ Wood/Coal Boiler Owner’s Manual
U. S.
14
Installation
9.
Aquastat-Immersion Control.
a. Remove the cover of the prewired
Aquastat-Immersion Control to adjust the
High and Low temperature limits.
i.
High Limit.
Set the High Limit pointer to
the temperature at which contacts are
to open to prevent the boiler from
overheating. Normal setting for the High
Limit is 185º. Always set the high limit
20º or more above the low limit.
ii.
Low Limit.
Set the Low Limit pointer to
the lowest water temperature you would
like the boiler to maintain. Normal
setting is 160º. Always set the high limit
20º or more above the low limit.
b. Insert the probe well into the left-front
receptacle located on the top of the Boiler
and tighten to secure.
c. Squeeze the entire tube of heat-
conductive grease (included) into the
probe well, and then insert the Aquastat-
Immersion Control probe into the probe
well, and secure.
10.
4
″
Domestic Hot Water Coil (Optional).
a. Unscrew & remove the 4
″
plug located at
the upper left on the back of the ENERGY
KING Wood/Coal Boiler model 35EK-D or
45EK-D.
b. Apply pipe joint compound (not included) to
the threads of the 4
″
domestic hot water
coil.
c. Insert the 4
″
domestic hot water coil into
the opening at the upper left on the back of
the ENERGY KING Wood/Coal Boiler and
turn clockwise until tightened.
d. Connect your domestic water supply
according to the coil manufacturer’s
instructions.
11.
24-V Wall Thermostat.
Locate the 24-V Wall
Thermostat provided with your ENERGY
KING heating appliance in the living area of
the home and install according to the
thermostat manufacturer’s installation
instructions (
Supplement B
).
12.
Wiring.
Do not connect power to your
ENERGY KING
Wood/Coal Boiler until the
installation is complete.
Once you’ve
completed the installation of your ENERGY
KING Wood/Coal Boiler, you may connect
your 110V power supply in to the left side of
the control box. Please see
Appendix A:
Wiring Diagram
.
Blue
Black
Figure 5: Aquastat-Immersion Control
Figure 7: Aquastat-Immersion Control,
Mounted
Risk of electric shock.
Disconnect power at the service
panel or breaker box before servicing
ENERGY KING Wood/Coal Boiler.
Figure 6: Probe Well
Содержание 35EK-D
Страница 2: ......
Страница 4: ......
Страница 8: ...Rev 08 24 10 ENERGY KING Wood Coal Boiler Owner s Manual U S 2 This page is intentionally left blank...
Страница 42: ...Rev 08 24 10 ENERGY KING Wood Coal Boiler Owner s Manual U S 36 This page is intentionally left blank...
Страница 43: ...Rev 08 24 10 ENERGY KING Wood Coal Boiler Owner s Manual U S 37 Appendix A Wiring Diagram...
Страница 44: ...Rev 08 24 10 ENERGY KING Wood Coal Boiler Owner s Manual U S 38 This page is intentionally left blank...
Страница 46: ...Rev 08 24 10 ENERGY KING Wood Coal Boiler Owner s Manual U S 40 This page is intentionally left blank...
Страница 50: ...Rev 08 24 10 ENERGY KING Wood Coal Boiler Owner s Manual U S 44 This page is intentionally left blank...
Страница 54: ...Rev 08 24 10 ENERGY KING Wood Coal Boiler Owner s Manual U S 48 This page is intentionally left blank...
Страница 58: ......
Страница 59: ......
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......
Страница 71: ......
Страница 72: ......
Страница 73: ......
Страница 74: ......
Страница 75: ......
Страница 76: ......