ENERGY KINETICS Ascent Combi Boilers Скачать руководство пользователя страница 5

Ascent Combi & Ascent Plus Combi Gas Heat 

– PN 10-2099 – May 2020 

5

 

COMMONWEALTH OF MASSACHUSETTS 
When the boiler is installed within the Commonwealth of Massachusetts: 

 

This product must be installed by a licensed plumber 

 

If antifreeze is used, a reduced pressure backflow preventer device shall be used. 

 

 

 
INSTALLER NOTE: 

 

ALL INSTALLATIONS MUST BE MADE IN ACCORDANCE WITH ALL NATIONAL, STATE AND 
LOCAL, PLUMBING, HEATING AND ELECTRICAL CODES THAT MAY DIFFER FROM THIS 
MANUAL AND IN ACCORDANCE WITH THE FOLLOWING CODES, AS APPLICABLE:

 

 

N.F.P.A. No. 70:  National Electrical Code A.N.S.I. / N.F.P.A. No. 211: Chimneys, Fireplaces, 
Vents and Solid Fuel Burning Appliances A.N.S.I. Z223.1/N.F.P.A. No. 54: National Fuel Gas 
Code If this gas-fired boiler is converted to oil-fired by field mounting a listed oil conversion 
burner, then install in accordance with A.N.S.I./N.F.P.A. No. 31: Installation of Oil Burning 
Equipment 

 

These codes are available from: 
National Fire Protection Association 
1 Batterymarch Park 
Quincy, MA 02269-9101. 

 

A hot water boiler installed above radiation level or as required by the Authority having 
jurisdiction, must be provided with a low water cutoff device. 

 

A boiler should be installed in such a manner that, if the pressure vessel or any connection 
thereto should leak, the resulting flow of water will not cause damage to the area in which it 
is installed. 

 

 

A hot water storage tank should be installed in such a manner that, if the storage tank or any 
connection thereto should leak, the resulting flow of water will not cause damage to the area 
in which it is installed. 

 

A boiler’s pressure relief valve, hot water storage tank T&P relief valve, backflow preventer, 
and all other devices must be piped to the nearest drain to avoid damage in the event the 
valve is actuated. 

 

Make sure relief discharge pipes from all reliefs are properly placed to safely contain 
discharge.  Make sure relief discharge pipes, such as from a boiler or a hot water storage 
tank, will safely contain hot water and/or boiling water.  Make sure relief discharge pipes, 
such as from a boiler or a radiant heating system, will safely contain water treated with boiler 
chemicals and/or antifreeze.  Reliefs include the boiler pressure relief valve, the back flow 
preventer discharge port, and the domestic hot water tank temperature and pressure relief 
valve.  Any other reliefs, such as from radiant heating systems, must also follow these 
guidelines. 

Содержание Ascent Combi Boilers

Страница 1: ...followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or a...

Страница 2: ...rner Do not use or store laundry products paint varnish thinner or other such chemicals near or in the same room as the burner boiler These chemicals cause creation of acids in the burner heat exchang...

Страница 3: ...place any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety information above 2 Set the thermostat s and aquastat s to their lowes...

Страница 4: ...INSTALLER CITY STATE DATE INSTALLED NOTES TABLE OF CONTENTS Page Topic 2 Please Read This First 4 Record of Installation 4 Table of Contents 5 Installer Note 6 Ascent Combi Boiler 6 Ascent Combi Boile...

Страница 5: ...must be provided with a low water cutoff device A boiler should be installed in such a manner that if the pressure vessel or any connection thereto should leak the resulting flow of water will not ca...

Страница 6: ...t all times This is similar the way traditional tankless coil boilers operate although they typically maintain significantly higher temperatures than are required by the EK1T Ascent Combi and the EK1T...

Страница 7: ...and peak performance and to verify proper performance of all safety devices PERIODIC MAINTENANCE The Ascent Combi and the Ascent Plus Combi boilers require minimal attention from the user Daily inspe...

Страница 8: ...tage of the trade list price of such pressure vessel at the time the warranty claim is made as determined in the following YEAR 1 st 11 th 12 th 13 th 14 th 15 th 16 th 17 th Percent of Trade list Pri...

Отзывы: